5. Sleep Mode Setting
Press the MENU button five times
to advance to the "Sleep" setting.
The default setting is 30 seconds.
Continue to press the SET button until the desired sleep setting
is displayed.
6. Screen Lock Setting
Press the MENU button six times to
advance to the "Screen Lock" setting.
The default setting is unlocked. Press the SET button once to
lock the screen. In this setting the screen will not rotate 90º.
Press the SET button once more to unlock the screen.
When all of your settings are adjusted to your preference, cycle
to the end of the menu or leave idle for 10 seconds and reinstall
the battery cover. Do not over-tighten screws.
Thermometer Accuracy & Response
Each thermometer is factory-calibrated. A certificate of
conformance is included. If for any reason you want to confirm
calibration you can perform an "ice water test". From room
temperature of 74º F +/- 5º F (23ºC +/- 3ºC), the thermometer
will read cold temperatures of an ice bath within 3 seconds, to
an accuracy within 1ºF (0.6ºC).
Calibration Procedure
You will need a cup of ice cubes with water added to just below
the top of the ice . Do not over fill with water. Ice should not be
floating. Push button to extend probe. Insert tip of probe halfway
down into the ice and stir for five seconds. Keep the probe tip
within the spaces between ice cubes. Avoid constant direct
contact with ice. The thermometer should read 32º F +/- 1º F. If
the display is within this temperature range your thermometer
is accurately calibrated. If the temperature reading is out of the
suggested range, adjust using the 4. Calibration Setting.
8
This symbol indicates that the product cannot be
disposed of in the trash. For instructions regarding
proper disposal of this product in Europe, please
visit www.weber.com, and contact the importer
listed for your country. If you do not have internet
access, contact your dealer for the importer's
name, address and telephone number.
20s
32˚
F
40s