TS EN 60669-2-1
Complies with ROHS Regulation Directive
2002/95/EC
360° MOTION SENSOR WALL SURFACE
USAGE AREAS
• At the building entrances, stair vestibules
• At the long halls within the flats
• At the places required within the flats
• At covered parking lots
• At the requisite locations within the hotels
• At the Schools, hospitals, Oil Filling Stations, etc.
"OFFERS ENERGY SAVING FEATURE"
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation and general
view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high than 240 voltages.
• Do not apply any liquid.
• Protect from stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install and
apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Fix the bulbs before operating.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
• The product should be mounted minimum 50 cm or more away from lamps or fluorescent
lamps.
• The detection range(diameter) of the ceiling type motion sensor models is 9m ± 1m. The
products are less effective for the narrow areas less than 9 m diameter. For narrow areas we
can recommend our 10464 model because it has distance settings.)
SPECIFICATIONS
Operating Voltage
230-240V~ 50/60 Hz
Detection Angle
360 °
Mounting Height
2.8 m.
Detection Range
9 m.
Time Settings
5 sec. ± 1sec. / 5 min. ± 10 sec.
Lighting Load
Max 1000W Incandescent
Max 400W Fluorescent
Protection Class
IP20
Operating Temperature
-20 °C ~ +40 °C
Detection range is determined at the temperature of +20 °C.
SETTING
Daylight Setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.
Control dial set
= Daylight operation approx. 2000 lux.
Control dial set
= Night-time operation approx. 2 lux.
Time Setting
Light ON time can be adjusted continuously from
"5 sec ± 1 sec. / 5 min ± 10 sec." If you turn the knob
clockwise device will operate at minimum time.(10 second)
Control dial set min = Shortest time (5 sec. ± 1 sec.)
Control dial set max = Longest time (5 min. ± 10 sec.)
NOTE : Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to test
again. Be sure that there is no motion by this period.
10361
max
min
info@na-de.com.tr
MOUNTING
(b)
(a)
DETECTION AREA
TROUBLESHOOTING
MALFUNCTION
• Lamp is off
10361
• There is no
electricity on the
device
• Continuously
lamp is on
• Change perception
area in device
DETECTION AREA
Detection area of motion sensors depends on the angle between PIR detector and moving direction,
temperature , mounting style and mounting place. Temperature is very important for operation
for motion sensor like all electronic devices. Using higher value of loads written on manuals and
packages will decrease temprature inside the device when using Na-De Motion Sensor. As a result
detection range will decrease and may cause defect of electronic components. Environment
temperature will also cause decrease of detection range. Detection range give is determined at
+20°C. If the weather is hot, it will decrease.
Walking targential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able to
cut vertical areas. Detection range of The detection distace of 10361 model is 9 m as diameter
and 4,5 m as radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to wear
parts, damage or defects caused by improper treatment or maintenance. Further consequential
damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well packed
complete with a brief description of the fault, a receipt or invoice ( date of purchase and dealer's
stamp) to the appropriate Service Center.
•
www.na-de.com.tr
Use this part surface mount aparate) when making surface mount
Place the aparton the ceiling shown by (a)
Pass the cables through the hole shown by (b)
LS
Lamp
N
L
Connect the line cable to the terminal shown by L
Connect the neutral cable to the terminal shown by N
You can also connect the neutral cable of lamp from here
Connect line cable of the lamp to the terminal shown by LS
Mount the body to ceiling part
Ceiling
360°
4.5 m.
4.5 m.
9 m.
CAUSE
• Daylight adjustment set to
• Control daylight setting and
night-time mode during daytime
re-adjust
operate
• Fit the bulp into the lamp holder,
• Bulb faulty or there is no
if it still does not operate, change
connection
the bulb.
• Power switch off or no electricity
• Check the electricity and power
on.
• Fuse faulty
• Change the fuse.
• Fuse switch off or fuse faulty
• Check the fuse if necessary use
a new fuse.
• Connection faulty.
• Check the connection cables.
• Continuously movement in
• Check the detection zone.
detection zone
• Cars on the streets are being
• Avert it is being detection.
detected.
• Wind, rain, snow is moving to the
• Change detection zone, change
trees & bushes or open windows in
site of installation.
detection zone.
• Sudden temperature changes due
• Change site of installation or
to weather(wind, rain, snow) or the
keep the reasons away.
air expelled from fans.
• Different ambient temperatures.
• Change site of installation.
Walking directly to the sensor
(lower detection range)
Figure 1
SOLUTION
KK-10361_150416_EN_00