Placing Tool In Service - Ingersoll Rand CE12T–EU Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
LUBRICATION
Ingersoll–Rand No. 10
Always use an air line lubricator with this Tool.
We recommend the following Lubricator Unit:
For International – No. 8LUB12–A3
Before starting the inside Trigger Handle Tools and after
each two or three hours of operation, unless the air line
lubricator is used, detach the air hose and inject about 3 cc
of oil into the air inlet.
INSTALLATION
Air Supply and Connections
Always use clean, dry air at 90 psig maximum air
pressure. Dust, corrosive fumes and/or excessive moisture
can ruin the motor of an air tool.
The filter removes dust and moisture.
Model
CE12T–EU
H
Tested in accordance with PNEUROP PN8NTC1.2 under load
Tested in accordance with ISO8662–2

PLACING TOOL IN SERVICE

SPECIFICATIONS
Blows per
Piston Stroke
minute
in (mm)
800
7.4 (188)
Make sure all hoses and fittings are the correct size and
are tightly secured. See Dwg. TPD905–1 for a typical
piping arrangement.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
H
Sound Level
dB (A)
Pressure
98.6
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
Vibrations
Level
Power
m/s
111.6
23.1
2