20 English
Protective Guard for Routing Blade
As a protection measure, the protective guard for
EN
the routing blade 8 must always be mounted (ex-
ception: vertical joint connection). Push the pro-
tective guard 8 from below onto the stop 6 and
allow it to engage.
Operation
Switching On and Off
To switch on the machine, push the On/Off switch
16 forward and press it down at the front to lock
on.
To switch off the machine, press down the On/Off
switch 16 at the rear so that the switch springs
back to the off position.
Adjusting the Depth-of-cut
The routing depth is adjusted with the thumbwheel
17. The thumbwheel must latch in the respective
position. The corresponding values are preset for
the most common biscuit connections:
Biscuit
Nr. 0
Nr. 10
Nr. 20
Simplex
Duplex
Maximum
For special applications, the routing depth can be
variably adjusted from 0 – 19.0 mm:
Set the thumbwheel to the "max." position. Push
the machine forward until the routing blade has
reached the desired routing depth. Set the depth
stop adjustment 18 to this measure by loosening
the lock nut 20 and turning the adjustment screw
19 (1 revolution = 0.7 mm). Tighten the lock nut
again.
Adjusting the Stop 6
Adjusting the groove height
With the adjustable height stop 6, the dis-
tance between the upper surface of the work-
piece and the intended groove can be set.
Loosen the locking screw 10 and set the height of
the groove at scale 14. Tighten the locking screw
10 again.
FDF-EN / 0802
Setting
Routing depth
0
8,0 mm
10
10,0 mm
20
12,3 mm
S
13,0 mm
D
14,7 mm
max.
19,0 mm
NOTE:
In order to position the groove centred in the
workpiece, the adjustable height stop must be set
to half of the workpiece thickness.
Example: For an 12 mm thick workpiece, set the
height scale to 6 mm.
The correct groove height must be determined
through practical testing according to material
thickness and type of material.
Index stop
Three different groove heights can be set with the
index stop 11. The index stops are factory set to
16, 19 and 25 mm.
Loosen lock nut 12 and turn stop screw 13 until
the desired height is reached. Tighten the lock nut
again.
Always turn the index stop until it latches in the re-
spective position.
Adjusting the groove angle
The stop 6 enables easy cutting of grooves
on mitre joints.
Loosen locking screw 21 and set the groove angle
at scale 22. Tighten locking screw 21 again.
Changing the tool
Disconnect the plug from the power
source before making any adjust-
ments, changing accessories, or stor-
ing power tools.
Such preventive safety measures
prevent accidental start of the power
tool.
Wear safety gloves for tool chang-
ing.
The tool insert can become very hot
after working for long periods and/or
the cutting edges of the tool insert
are sharp.
Protect cutting discs against shock and im-
pact.
Operation