• Electrical function check
− Start machine
− Actuate operating element.
Check that the machine stops!
Check whether the machine stops when the EMERGENCY
STOP button is pressed.
4
Recurring technical checks
In order to guarantee faultless and durable function, the
following checks must be performed regularly:
• faultless function
• no recognisable manipulation
• secure fastening of the components
• leak tightness of the cable entries
• no loosened cable connections
5
Behaviour in the case of an error
Complete functional test after rectification of the error.
Carry out a complete functional test after the rectification of
an error.
6
Technical Data
For dimensions, refer to "Dimensions" from page 25 on.
6.1 Operating elements
The following information applies for these items:
SNH 0100, SNH 0200, SNH 0300, SNH 0400, SNH 0500, SNH
0600, SNH 0700
Case material
Protection class
Operating ambient temperature
− without illumination
− with LED illumination
Storage temperature
Switching cycles
Max. torque
Installation diameter
LED illumination
− Power supply rated voltage
− Voltage range
− Current consumption
6.2 Switching elements
The following information applies for these items:
SNH 0001, SNH 0002, SNH 0003, SNH 0011, SNH 0012,
SNH 0013, SNH 0021, SNH 0022, SNH 0023, SNH 0031, SNH
0032, SNH 0033
Protection class
Ambient operating tempera-
ture
− without illumination
Storage temperature
Switching elements switching
principle
Utilisation category
Rated;insulation voltage U
Doc. # BA000612 - 09/2009 (Rev. A) ©2008 Wieland Electric GmbH
ATT ENTION
ATT ENTION
Plastic
IP 65 (IEC 60529)
SNH 0300: IP 69k
-30...+70 °C
-30...+55 °C
-50...+85 °C
> 50.000
2,5 Nm
22,3 mm
24 V AC/DC
12...30 V AC/DC
17 mA AC; 34 mA DC
II
-30...+85 °C
-50...+85 °C
Slow-action switching
element
AC15 A600: 250 V AC 3 A
DC13 Q600: 24 V DC 2 A
(EN 60947-5-1)
600 V
i
Connection technology (contacts)
Minimum switching voltage
Minimum switching current
Max. wire cross section
Thermal continuous current
Max. contact resistance
Max. bounce time
Min. positive break travel
Rated current I
/ rated
e
voltage U
e
B
value
10d
Mechanical service life
Electrical service life
(for rated load)
Contact material
Operating travel
6.3 Complete sets
The following information applies for these items:
SNH 1101, SNH 1102, SNH 1111, SNH 1112, SNH 1121, SNH
1122, SNH 1131, SNH 1132
Case material
Protection class
Protection class
Operating ambient tempera-
ture
Storage temperature
Switching elements
Positive NC / NO contacts
B
value
10d
Mechanical service life
(at +20 °C)
Electrical Data
7
Order Data
7.1 Operating elements
Item
Rotary unlocking,
with anti-lock
Rotary unlocking
Rotary unlocking,
protection class IP69,
for hygiene areas
Rotary unlocking,
with anti-lock,
illuminated
Lock release,
with anti-lock
Rotary unlocking,
with protective collar
Lock release,
with protective collar
Screw clamp connection
5 V
1 mA
2,5 mm²
16 A
20 mΩ
20 ms
3 mm
16 (10) A for 250 V AC
10 (6) A for 440 V AC
(EN61058-1)
250,000 switching cycles
6
1 x 10
switching cycles
6
1 x 10
switching cycles
AgNi
6 mm
Plastic
IP 65 (IEC 60529)
II
-25...+60 °C
-25...+85 °C
Depending on type:
1/0, 1/1, 2/0, 2/1
250,000 switching cycles
50.000
see "Switching elements"
Type
Part number
SNH 0100
R1.200.0100.0
SNH 0200
R1.200.0200.0
SNH 0300
R1.200.0300.0
SNH 0400
R1.200.0400.0
SNH 0500
R1.200.0500.0
SNH 0600
R1.200.0600.0
SNH 0700
R1.200.0700.0
6 / 27