GYS POWER HUB MODULE Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Translation of the original instructions
PREPARATION
Before wiring the product, make sure that all chargers are switched off and that no batte-
ries are connected (risk of short circuit).
1 Unscrew the cover (5) of the PHM (6 screws).
Connection inlet PHM
Remove the clamps from the power cables of the GYSFLASH chargers.
2
If the charging cables are too long
- Cut the cables to the desired length.
- choose the appropriate lug
crimp with appropriate pliers.
-
- Shrink tubing to the wall
The length of the cable must not be less than 1 m.
Pass the red cable through an input cable gland + (1) of the housing.
3
And the black cable in an inlet cable gland - (2) of the housing.
Screw the cables to the corresponding plate with the screws provided in
4
the bag (red cable to Cu plate + above / black cable to Cu plate - below).
Tighten the screws well (5 Nm) .
5 Tighten the cable glands used.
10
POWER HUB MODULE
(2.5 or 5 m depending on the GYSFLASH)
(10, 16 or 25 mm² depending on the GYSFLASH cable(s))
(use 25 mm of the 200 mm tubing heat-shrinkable supplied).