Translation of the original instructions
PHM output connection
Depending on the desired charging current:
choose a cable
1.
(not supplied)
Choose the corresponding cable lug
2.
crimp with an appropriate crimping tool.
3.
Recommendations on the maximum length of cables in metres, depending on their cross-section and current intensity.
6
100
120
25
15
12
35
21
17
50
29
25
70
41
34
Values given for the use of fully copper-plated cables.
7 Shrink the heat-shrinkable tubing provided.
Pass the red cable through an input cable gland + (1) of the housing.
8
And the black cable in an inlet cable gland - (2) of the housing.
Screw the cables with the screws provided in the bag (red wire at the
9
top / black wire at the bottom)
Tighten the screws well (5 Nm) .
10 Tighten the cable gland.
11 Replace the product cover.
POWER HUB MODULE
with the appropriate cross-section
(25, 35, 50, 70 mm² supplied).
140
160
180
200
220
11
9,2
8,2
7,4
15
13
11
10
9,4
21
18
16
15
13
29
26
23
21
19
(see recommendations table below)
I max (A)
240
250
260
280
̶
̶
̶
̶
̶
8,6
8,2
̶
̶
12
12
11
11
17
16
16
15
.
300
320
340
360
380
̶
̶
̶
̶
̶
̶
̶
̶
9,8
9,2
̶
̶
14
13
12
11
11
EN
400
̶
̶
̶
̶
̶
̶
10
11