TS EN
60669-2-1
Complies with ROHS Regulation Directive
2002/95/EC
10901 - 10912
CEILING - WALL TYPE HF MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE"
GENERAL SECURITY CAUTIONS
• Take of the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the prodct at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply and liquid.
• Protect from any stroke.
• Using ~230-240V voltage is so dangerous that only the specialist electricians
must install and apply.
CAUTIONS FOR INSTALL AND USAGE
• Installing must be carried out professional in accordance with applicable national wiring and
electrical operating conditions.
• Turn off the mains before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the wall/ceiling.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10-15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight setting abruptly.
• Do not make a second adjustment before you get a result from the first setting of the the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• If you cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
SPECIFICATIONS
Operating voltage
: ~230-240 VAC / 50 Hz
Detection angle (10901 ceiling)
: 360°
(10912 wall)
: 180°
Mounting height
: 2.8 m (10901)
: 2.2 m (10912)
Detection range (10901)
: 6m / 14m (adjustable)
(10912)
: 6m / 25m (adjustable)
Time settings
: 10sec. ± 1sec. / 5min. ± 10sec.
Lighting load
: 1000W incendescent
: 400W Flourescent
Lux adjustment
: 2 - 2000 lux
Protection class
: IP20
Operating tempreture
: -20 °C ~ +40 °C
HF Frequency
: 10.525GHz
Detection range is determined at the temperature of +20 °C.
SETTING
(b)
(a)
Time
(a) Time setting
Light ON time can be adjusted continuously from "10 sec. / 5 min." If you turn the knob
anticlockwise device will operate at minimum time. (10 seconds)
Control dial set to - = Shortest time (10 sec. ± 1 sec.)
Control dial set to + = Longest time (5 min. ± 10 sec.)
(b) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob anticlockwise device will operate at dark.
Max. Lux
= daylight operation approx. 2000 lux.
Min. Lux
= night-time operation approx. 2 lux.
(c) Distance setting
Distance adjustment is set down to sense how distance long. This product delicately sense any
small move so you should be carefull when the adjust the maximum distance..
10901
Control dial set to - = Shortest distance (6 m.)
Control dial set to + = Longest distance (14 m.)
10912
Control dial set to - = Shortest distance (6 m.)
Control dial set to + = Longest distance (25m.)
10901 Ceiling
10912 Wall
Class ll
(c)
Lux
Sene
info@na-de.com.tr • www.na-de.com.tr
MOUNTING
As shown figure (a) mount the product base
to the wall with screws which is given
with the product.
As show figure (b) pass the cables through
the hole.
Pin holes
Connect the line (phase) cable to the terminal shown by L
Connect the nort cable to the terminal shown by N
You can also connect the notr cable of lamp from here.
Connect the line out cable (for the lamp) to the terminal
shown by LS
(e)
After L, N, LS terminals connection please
fix the product on the wall as shown
figure (c).
DETECTION AREA
10901
Ceiling
360°
7 m.
7 m.
max. 14 m.
Detection range

TROUBLESHOOTING

MALFUNCTION
CAUSE
• Lamp is off
• Day light adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty
• There is no
• Fuse switch off or fuse faulty
electricity on the
device
• Connection faulty.
• Continuously
• Continuously movement in
lamp is on
detection zone
• Cars on the streets are being
detected.
• Thiny walls (wooden, plaster
plastics) may cause unexpected
detections.
• Change in
• Same small motions can be
detections range
resulted by unxpected detections.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase and
dealer's stamp) to the appropriate Service Center.
(a)
(b)
(a)
(c)
(c)
Wall
max. 25m
Detection range
SOLUTION
• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or
keep the reasons away.