UNPACKING
Carefully remove unit from carton. Remove the foam in the housing. Refer to the Supplied
Parts list on page 2 to verify that all parts are present.
GENERAL SAFETY INFORMATION & WARNINGS
1.
Electric Service supply must be 120V 60Hz.
2.
Follow all local safety and electrical codes as well as NEC (National Electrical Code) and OSHA
(Occupational Safety and Health Act).
3.
This unit must be properly grounded.
4.
Always disconnect the power supply prior to servicing the fan, motor or junction box.
5.
Do not bend or kink the power wires. Protect from sharp edges, oil, grease, hot surfaces,
chemical or other objects.
6.
Do not install where the room air temperature will exceed 40ºC (104ºF).
7.
Do not install over a tub or mount in a shower stall enclosure.
8.
Do not use to exhaust hazardous or explosive vapors.
9.
Do not install in a cooking area.
10. Do not install this fan vertically in a wall.
11. Use this unit in the manner intended by the manufacturer. If you have any questions please call
the manufacturer (customer service number located on last page).
12. Installation work must be carried out by a qualified person(s) in accordance to all local and safety
codes including the rules for fire-rated construction. For use in non-fire rated installations only.
13. Sufficient air supply is required for proper combustion and the exhaustion of gases through the
chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of NFPA
(National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration
and Air Conditioning Engineers) and the local building code authorities.
14. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
15. Fans should always be vented to the exterior and in compliance with local codes.
16. Do not use this fan with any solid state control device; such as a dimmer switch. Solid-state
controls may cause harmonic distortion, which can cause a motor humming noise.
17. Prior to service or cleaning this unit, shut off power supply at the panel and lock to
prevent the power from being turned on. If the panel cannot be locked, clearly mark
the panel with a warning tag to prevent the power from being turned on.
18. Do not install in a ceiling with insulation greater than R40. (This is required for installations in
Canada only.)
19. Duct work should be installed in a straight line with minimal bends.
20. Duct work size must be a minimum of the discharge and should not be reduced.
Reducing the duct size can increase fan noise.
21. This ventilating bath fan is intended for residential use only in 1-2 family dwellings.
22. Never place a switch where it can be reached from a tub or shower.
23. Make sure that the electric service supply voltage is AC 120V, 60Hz.
24. Always disconnect the power source before working on or near the unit.
25. This unit is designed and tested to be a supplemental heater for use with a timer or a switch.
It is not intended to be used as the primary source of heat and controlled by a thermostat.
Item# 398999
5
Effective/Rev. date: March 15, 2012