1 Button
2 Front part of the casing
3 Suction hose for detergent
4 Weight
5 Foot valve
6 Hook
7 Hose for detergent solution
8 Fastening hole
9 Outlet of detergent solution
10 Nozzle insert
11 Input of detergent
12 Floading ring
13 Water inlet
14 Locking
8
Operating and Functional Elements
Device installation
Press on the lock and remove the cabi-
net front.
Mark 3 fastening holes on the wall
through the back of the casing.
Drill 3 holes with a diameter of 8 mm ap-
prox. 40 mm deep into the wall.
Insert the included dowels all the way
into the holes.
Screw the included screws into the top
two dowels.
Hook the cabinet back onto the screws.
Turn in the bottom screw and tighten all
the screws.
Select the nozzle insert for the desired
mixing ratio:
– 2
EN