p50_61_uk_SRE30x.qxd:p32_41_uk_SRE70xTC.qxd 18-11-13 15:42 Page 59
transportation cap
59
P
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, store the heater in a dust-free place in its
original packaging. Any unused fuel cannot be used the next heating season. We
therefore recommend that you burn up all fuel prior to storing. If there is still
some fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using the
heater follow the instructions again (starting from section A and as specified).
Q
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank from the heater and remove the fuel filter.
Some drops may leak from the filter; keep a cloth at hand. Store the fuel filter
and the removable tank outside the heater.
3
Place the transportation cap into the position of the fuel filter. Press it tight.
The transportation cap will, as much as possible, prevent oil leakage from the
heater during transport.
4
Always move the heater in an upright position.
5
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
pump into the empty fixed tank. Follow the same procedure if the fuel tank
contains water.
R
SPECIFICATIONS
IGNITION
FUEL
SUITABLE SPACE MIN-MAX
HEATING CAPACITY MIN-MAX
MAINS
ELECTRIC CONSUMPTION BURNING
ELECTRIC CONSUMPTION IGNITION
ELECTRIC CONSUMPTION
QUICK IGNITION MODE
WEIGHT
FUSE RATING
DIMENSIONS (HxWxD)
ACCESSORIES
REMOVABLE TANK CAPACITY
BURNING TIME PER TANK
(100% CAPACITY)
Specified values are indicative
ELECTRICAL
PARAFFIN
48 - 120 m
3
1,5 kW (125 g/h) 3.0 kW (250 g/h)
230 V~ / 50 Hz
22 W
660 W
100 W (heater not burning)
10 kg
5 A / AC 250 V / 5 X 20 mm
45.5 x 40 x 30.7 cm
TRANSPORTATION CAP
5,8 LITRES
18,7 h