Ingeteam Ingecon EMS Home Serie Manual De Instalacion Y Uso página 58

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
Ingeteam
Inverter Monit.
VAC
Inverter output voltage (V).
IAC
Current through inverter (A).
FAC
Frequency generated by the inverter (Hz).
SAC
Apparent power (VA) through the inverter.
PHICOS
Cosine of Phi. Cosine of the phase shift angle between the voltage and current supplied by the
inverter.
Battery Monit.
VBAT
Battery bank voltage (V).
IBAT
Battery bank current (A). Positive for discharge, negative for charge.
SOC
Estimation of the battery bank state of charge (%).
STATUS
Operational status of the battery bank. The following states may be shown: STOP, DISCHARGE,
CHARGE, ABSORPTIOn, FLOTATIOn or EqUALIZATIOn.
BATTEMP
Battery bank temperature (°C).
Grid Monit.
VAC
Public grid voltage (V).
IAC
Public grid current (A).
FAC
Public grid frequency (Hz).
SAC
Apparent power (VA) the inverter is feeding/absorbing to/from the public grid.
STATUS
Indicates whether the inverter is connected or disconnected to the public grid.
Alarm Monit.
ALARM
Status of inverter alarms.
InV. nUM.
number allocated to the inverter through the menu accessible in the display for identifying it on a
ModBus network.
CODE1
Unit operating code. This can be requested from Ingeteam's customer services.
CODE2
Unit operating code. This can be requested from Ingeteam's customer services.
Sn
Serial number.
Total Monit.
TOTE
Total energy (kWh) delivered by the inverter and drawn by the grid since the last time the counter
was reset.
T COn
number of hours the inverter has been operating.
nUMCOn
number of public grid connections made during all hours of operation.
Partial Monit.
PART E
Partial energy (kWh) delivered by the inverter and drawn by the grid since the last time the counter
was reset.
TP COn
number of hours the inverter has been connected to the grid since the counter was last reset.
nPCOn
number of connections to the public grid since the counter was last reset.
fw Monit.
FW VER.
Unit firmware version.
DFWVER.
Unit display firmware version.
D. BOOT
Internal program version.
58 - English
display control
ABH2000IKE02_ - User manual

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido