Note! Acetone can damage the display seal. Gerät: Vor der Reinigung Gerät ausschalten! www.q-nix.com/support com/support Verwenden Sie ein feuchtes, fusselfreies Tuch Automation Dr. Nix GmbH & Co KG Automation Dr. Nix GmbH & Co KG 1.6 Disposal und milde Reinigungsmittel, bei Verschmutzun- Robert-Perthel-Strasse 2...
QNix 5500 ® 3. Initial Operation 3.1. Insert Battery This device includes: 2 mignon batteries AA (LR6 / FR 6 / AM3) • To unlock the cover, turn the ring anti-clockwise. • Lift off cover. • Insert or replace battery. •...
Página 7
Connect the probe to the probe cable • Screw the probe together with the cable. For this purpose, always turn only the union nut of the cable. A turning movement of the angled cable connection can lead to permanent damage of the electrical contacts. This entails the loss of guarantee. •...
QNix 5500 ® 4. Operation and Controls 4.1. About Operation Please note the following instructions to ensure conclusive results: • Hold the device by the probe holder. • Carefully place the device or the probe perpendicular on the surface. • Ensure the probe makes good contact with the surface and avoid the probe shaking.
4.3. Measurement Display The measurement display contains the areas Status bar Measurement area Analysis area Depending on the context, the measurement display will show the following information: Section Symbol Description Status bar Calibration done Display of the actual substrate status Battery level 100 % / 50 % / 25 % / empty Note! When the batteries are below 50 %, a warning screen will appear.
QNix 5500 ® 4.4. Measurent with volatile memory Please note that it is not possible to display earlier measurements. Safing of data only is for rough statistics. • If necessary, start zero-adjustment. • Apply the probe and take a measurement. Sensor ring colours •...
4.6. Delete User‘s Adjustment Pressing and holding the button until the countdown for switch-off starts will delete the last measure- ment results. If you repeat this three times within 5 seconds, the user‘s adjustment will be deleted also – the gauge goes back to factory status. When exceeding 5 seconds the counted repeats are set back to 0. In case of a user‘s adjustment, the according symbol is shown in the status bar.
The equipment must be repaired by our service partners or by a manufacturer authorised technician. If you have any questions, please contact your local retailer or our support: www.q-nix.com/support Automation Dr. Nix GmbH & Co KG Robert-Perthel-Strasse 2 50739 Cologne – Germany...
7.1.2. Gauge Electrical Data Electrical Data Protection rating Device power supply 2 x Batterys 1,5 V (type AA) Battery life without operation at min. 50 % > 1 year battery capacity Battery life at one measurement per second approx. 60 000 measurements 7.2.
QNix 5500 ® 7.2.2. Probe Electrical Data The probes may only be used with the gauges QNix® 9500 and QNix® 5500. 7.3. Measuring Data Measuring Data Principle of Measurement Magnetic field principal Magnetic field principal Magnetic field change, Eddy current Hall effect As per standard (varies by model) DIN EN ISO 2808,...