3.2. Mains connection

All the models can be supplied for 110-120 / 220-240VAC and 50-60Hz, depending on
the country (see characteristic label on the amplifier), being the approximate power consumption
at full power:
MODEL
POWER C.
Contact our Technical Services whenever a supply voltage change should be needed.
WARNING!: By convention, the mains wire colour assignment is the following:
- BROWN
- BLUE
- YELLOW/GREEN
The PAM2100/4100/6100 models have been provided with a soft start that limits the
current peak when starting up the amplifier to a maximum of 25A. This system enables the
simultaneous connection of various amplifiers without overloading the magneto-thermal switches
and also increases the electronics reliability thanks to the suppression of the initial transitories.
The PAM1100 do not need this system because of their lower power.
Make sure that the mains wire is not engaged with the signal wires in order to avoid
possible hum.
A set of slow blow fuses on each power module, on the transformer primary and on the
soft start circuitry (see table) is disposed in the amplifier as a protection against
overloads. Whenever one of this fuses blows, it must be replaced by another one of the
same characteristics. If it blows again, please consult our Technical Service.
FUSES
Mains
Soft start
Power
CAUTION: Fuse substitutions have to be performed by a qualified technician.

3.3. "Earth Link" switch

The Earth Link or Ground Link switch (12) prevents possible ground loops when various
machines in the same chain are connected to earth. This switch makes possible to disconnect the
electrical ground from the mechanical ground. Whenever hum arises, alternatively switch the earth
link switches of the amplifier and others components of the audio chain.
6
All manuals and user guides at all-guides.com
PAM1100
PAM2100
1390VA
2590VA
=
=
=
PAM1100
PAM2100
T 12A
T 16A
-----
T 0.250A
T 12A
T 16A
-----
-----
PAM4100
PAM6100
4000VA
6260VA
Phase
Neutral
Earth
PAM4100
PAM6100
T 16A
T 16A
T 0.250A
T 0.250A
T 12A
T 16A
T 0.250A
T 0.250A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pam2100Pam4100Pam6100

Tabla de contenido