How to proceed:
• Loosen the self-tapping screw until the the screw tip is sunk into the casing of the clamping
screw.
• Carefully remove the quartz glass by pulling it forward with a slight turning movement.
• Carefully push the quartz glass with the O-ring as far as the stop in the unit head during in-
stallation.
– Ensure that the O ring is located in the gap between the unit head and the quartz glass.
• Tighten the clamping screw up to the stop.
• Wipe the quartz glass with a damp cloth to remove dirt and fingerprints.
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if freezing temperatures
are expected.
How to correctly store the unit:
• Thoroughly clean the unit and replace damaged components.
• Store the unit in a dry and frost-free place.