PCX-RIX8i
Remote input expander with fast inputs
EN50131-3:2009
EN50131-1:2006+A1:2009
PD6662:2010
Security Grade 2
Environmental Class II
E N G L I S H
Installation Notes
NOTE: The expander module can be mounted on typical building
materials; such as wood, PVC, brick or metal etc. If you do encounter
any problems with different surfaces, please contact
customer.support@pyronix.com.
Programming Menu's Required:
A
INSTALL RIX
B
PROGRAM INPUTS
C
LEDs:
POWER = GREEN.
OK = BLUE. Flashing = Data OK. Off = No Data.
FAULT = RED. Flashing = Not addressed properly. Off = No faults.
Specification
Input Voltage: 9-15V
Current Consumption: 45mA
Inputs: Programmable
Inputs: DEOL, SEOL, NC, Inertia
Dimensions Plastic Box: 173 x 125 x 32mm
Dimensions PCB: 128 x 87 x 16mm
Colour and Casing: White 3mm ABS with clear polycarbonate window.
Indication: LEDs (Power, OK and Fault)
Temperature: Storage:-20°C to 60°C
Certified:-10°C to 40°C
Nominal:-10°C to 50°C
Front and rear tamper protected
Warranty
This product is sold subject to our standard warranty conditions and is warranted
against defects in workmanship for a period of two years (batteries excluded). In the
interest of continuing care and design, Pyronix Ltd reserves the right to amend
specifications, without giving prior notice.
Product Warning Information
For electrical products sold within the European Community. At the end of the
electrical products life, it should not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local Authority or retailer for recycling
advice in your country.
Compatible Products
The PCX-RIX8i can be connected to the following control panels/devices:
- PCX 46
- PCX 76i, 162i, 280i
- PCX 76iIP and 280iIP
- V2 GSM
Each control panel/device connects via the RS485 bus terminals: D1-,D2+,D3,D4.
0845 6434 999 (UK). +44(0)1709 535 225
START
D1-
ATE INPUTS
D2+
D3
D4
D1- D2+ D3
D4
PCX
PCX-LCD/EX
PCX-RIX8i
N/C
6K8
5K6
12v 0v
4K7
2K2
1K
ALARM
+ -
6K8
5K6
4K7
2K2
1K
Magnetic Contact
KX15DD
PCX-RIX8i
1
1
K
K
Shock Sensor
customer.support@pyronix.com
www.pyronix.com
RS485 BUS: 1km
D1-
D1-
D2+
D3
D3
D4
D4
PCX-ROX8R8T
PCX-RIX8i
PCX-RIX8+
D1- D2+ D3
D4
D1- D2+ D3
PCX-EXT-W
PCX-EXT-BK
PCX-PROX/INT
2
6K8
1
1
5K6
5K6
4K7
K
K
4K7
2K2
2K2
1K
1K
TAMPER
LED
5K6
4K7
2K2
1K
Magnetic Contact
C
PROGRAM INPUTS?
POWER
OK
Input
[01]
Input 01
LED1
LED2
(GREEN)
(BLUE)
Input Type [07]
Entry Delay 1
Input In
Area
[A
]
Input Attributes?
Inertia Input?
Yes
[1]
Gross Attack
[04]
Pulse Count
[01]
Pyronix Ltd, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
D1-
D2+
D3
D4
PCX-RIX8+PSU
PCX-ROX16R+PSU
D4
D1- D2+ D3
D4
PCX-RIX32-WE
PCX-RIX8i
5K6
1
1
4K7
12v 0v
K
K
2K2
1K
ALARM
+ -
TAMPER
LED
6K8
5K6
5K6
4K7
4K7
2K2
2K2
1K
1K
KX15DD
FAULT
LED3
(RED)
RS485 BUS: 1km
RIX(Address):
INSTALL RIX?
RIX Address?
0
RIX Installed?
No [0]
RIX1 RIX3 RIX12
RIX Installed?
Wired [1]
e.g.
PROGRAM INPUTS?
PCX-RIX8i
Input
[01]
Input 01
Input Type [07]
Entry Delay 1
Input In
Area
[A
]
Roller Shutter
Input Attributes?
Inertia Input?
Yes
[1]
Gross Attack
[04]
Pulse Count
[01]
>5s
RS485
END