--Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more
than 3LUX, the lamp should not work. If the ambient light is less than 3LUX (darkness),
the sensor would work. Under no induction signal condition, the lamp should stop
working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
otherwise the sensor lamp could not work!
NOTE:
--Should be installed by electrician or experienced person;
--Avoid installing it on the uneven object;
--There should be no hindrance and moving objects in front of the detection windows
to affect detection;
--Avoid installing it near air temperature alteration zones such as air condition,
central heating, etc;
--Considering your safety, please do not open the cover when you find the hitch
after installation.
--If there is difference between instruction and the function the product has, please
give priority to product and sorry not to inform you additionally.
SOME PROBLEM AND SOLVED WAY:
--The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
--The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to
affect to receive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed
in the instruction.
e. Please check if the moving orientation is correct.
--The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.
www.grupotemper.com