--When the sensor receives the second induction signals within the first induction, it will restart
to time from the moment.
--Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
--Adjust the stand-by period to "90s", when the sensor receives induction signal, the lamp will
be 100% on; 10sec later, the lamp dims quickly to 20% on for 90sec and then turn off. If the
sensor receives second induction signal within the stand-by period, the lamp will be 100% on.
Note: "+∞ "means lamp keeps on stand-by dimming level and never switches off.
"0s" means no dimming function
Note: when testing in daylight, please turn LUX knob to
the sensor light could not work!
NOTE:
--Electrician or experienced human can install it.
--Can not be installed on the uneven and shaky surface
--In front of the sensor there shouldn't be obstructive object affecting detection.
--Avoid installing it near the metal and glass which may affect the sensor.
--For your safety, please don't open the case if you find hitch after installation.
SOME PROBLEM AND SOLVED WAY:
--The load don't work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light is not on after sensing, please check if the working light corresponds to
the ambient light.
d. Please check if the working voltage corresponds to the power source.
--The sensitivity is poor:
a. Please check if in front of the sensor there shouldn't be obstructive object that affect to
receive the signals.
b. Please check if the signal source is in the detection fields.
c. Please check the installation height.
--The sensor can't shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power corresponds to the instruction.