10 TROUBLESHOOTING
Problems
The appliance does not switch on
The appliance does not suck in
material, or sucks only weakly
Power tool does not start (where power
tool socket is featured)
Dust comes out of appliance
Bad smells from appliance when in
operation
(*) If the motor stops and does not restart during operation contact the Service Centre.
We, Annovi Reverberi S.p.A, of Modena, Italy, declare that the following AR Blue Clean appliance(s):
Designation of appliance: Wet&dry vacuum cleaner
Model No.:
Rated power:
is (are) compliant with the following European directives:
2014/35/EU, 2014/30/EU, 2015/863/EU, 2011/65/EU, 2012/19/EU.
and was (were) produced in compliance with the following norms or standardised documents:
EN 60335-1; EN 60335-2-2; EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 62233; EN 50581.
Name and address of the person responsible for issuing the technical file: Stefano Reverberi / AR Managing Director
Via ML King, 3 - 41122 Modena, Italy
Date: 07.05.2019
MODENA (I)
Stefano Reverberi
Probable causes
No electrical power
Problems with the electric-electronic circuit
Accessories fouled
Filters dirty
Filter bags full
Tank full
Power tool plug not fitted into vacuum cleaner socket correctly
Switch off or turned to I
Filter not fitted
Filter damaged
Hose or connections damaged
Filters/ filter bags dirty
EC Declaration of conformity
3170
3270
3370
1,2 kW
1,2 kW
1,4 kW
(Original instructions)
Check that the plug is firmly in the socket and that the mains
voltage supply is present (*)
Contact the Service Centre
Check and clean the nozzles, extensions or hoses
Clean the filters
Empty / change filter bags
Empty the tank
Fit the plug properly
Turn switch to power tool/II position
Fit the filter
Replace the worn filter with a new one
Replace damaged parts
Replace filters/filter bags
3470
3570
3670
1,2 kW
1,6 kW
1,6 kW
Managing Director
ENGLISH
Remedies
13
EN