H-5458, S-21107
PORTABLE
EYEWASH STATION
WARNING! Depressurize tank by activating
pressure relief valve on the outlet stem
assembly.
1.
Loosen and remove bolts, nuts, clips and the clamp
from the tank. Raise the eyewash assembly from the
tank.
2. Fill tank with 5 gallons of clear, clean, potable water.
Add entire bottle of included water preservative
(S-21107). Then, fill with 5 more gallons of clear,
clean, potable water.
CAUTION! Do not overfill tank.
3. Replace eyewash assembly ensuring that the
eyewash assembly flag handle and the eyewash
sign on the vessel are facing the same direction.
Reclamp securely in place by tightening the nuts.
Replace clips.
4. Using the Schrader air intake valve, pressurize unit to
80 PSI. Be sure to use a clean air source.
WARNING! Do not use CO
pressure gas. Do not connect directly to any
external air or gas source.
5. Run unit momentarily to purge air and any
contaminants from system.
NOTE: Water should be drained and replaced
with fresh water and one bottle of water
preservative at least once every six months.
CAUTION! Keep away from heat.
PAGE 1 OF 3
1-800-295-5510
uline.com
ASSEMBLY AND OPERATION
or any other high
2
Pour le français, consulter la page 3
Eyewash
Assembly
Pressure
Release
Valve
Bolt
Clip
Clamp
Nut
Para Español, vea página 2
Eyewash
Assembly
Flag Handle
Nut
Clip
Bolt
0621 IH-5458