Uline H-1553 Manual De Instrucciones página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REMOVAL AND CLEANING
1.
Remove the pump and hold the outlet nozzle over
a container or bucket and tip slowly backward and
forward until the flow stops.
2. When the pump has been used to pump water
soluble liquids, rinse the pump by standing it in a
bucket of water and pump until empty.
1
3
4
5
6
10
2
7
8
PAGE 2 OF 6
INSTRUCTIONS CONTINUED
#
DESCRIPTION
9
1
Ball Handle
2
Plunger
3
Pumphead Cap
Seal Pack, Includes: 4, 5
4
Pumphead Scraper Seal
5
Pumphead Seal
11
6
Pumphead Seal Holder
15
Plunger Valve, Includes: 7, 8
14
7
Plunger Valve Flap
8
Plunger Valve Holder
16
9
Safety Strap (White)
10
Pump Body 200/55PP
11
Straight Spout Outlet Nozzle
Foot Valve, Includes: 12, 13
12
Foot Valve Flap
13
Foot Valve Holder
14
Drum Attachment Seal
15
Drum Attachment Cap
16
Drum Attachment Fitting, 2" BSP & 2" NPT
12
13
WARNING: Respect the toxicity of any chemical
being pumped. Read the product label for
advice on necessary eye, skin, inhalation
protection and protective clothing. Remember,
the pump will have a quantity of chemical
contained inside it when it is removed.
PARTS
1-800-295-5510
uline.com
ULINE PART NO.
MFG. PART NO.
-----------
HW
-----------
N/A
-----------
Y0366
H-1553-SEAL
SP_LDPE
-----------
Y0376
-----------
Y0375
-----------
Y0362
H-1553-PLUNG
VP
-----------
Y0358
-----------
Y0360
-----------
Y0353
-----------
N/A
-----------
Y3037
H-1553-VALVE
VF
-----------
Y0359
-----------
Y0361
H-1553-14
Y3036
-----------
Y3035
-----------
M63R
0721 IH-1553