INSTALLATION INSTRUCTIONS
NOTE: Pump (A) depends on the liquid flowing through
it for lubrication. DO NOT RUN THE PUMP (A) DRY!
1. Pump (A) should be located so that the water
source is within reach of 6 ft. reinforced inlet hose
(B). Inlet hoses longer than 6 ft. may prevent pump
from operating.
2. Check to be sure there is a washer in the inlet fitting of
inlet hose (B). Install reinforced inlet hose (B) on the
inlet side of pump (A). Make sure all connections are
tight. If connections leak, pump (A) will not operate.
CAUTION:
Inlet hose MUST be reinforced and no longer than 6 ft.
Outlet hose must be no longer than 25 ft.
Hoses that expand and contract will not allow the
pump to operate.
PRIMING AND STARTUP
1. To prime pump (A), tilt pump up to fill the pump cavity
to wet the impeller.
1
A
Outlet
2
Outlet Hose
1
5
STOP
Inlet
B
Water Source
Outlet
A
Inlet
3 ft. Max.
Vertical
A
B