WARNING
LP hose is a tripping hazard.
Special Care must be observed.
4. Open the LP tank valve fully by turning
counterclockwise.
5. Using a long
ignited match
(fireplace match),
place flame
directly over the
burner. If using a
short/paper book
match, first place
the unlit match into the match holder which
is attached by a chain to the stand, then
light the match.
Match Holder
6. DO NOT stand with head or arms over
burner. Slowly turn the regulator control
knob clockwise until burner is lit.
7. When the burner is lit, turn the regulator
control knob to the desired heat output
position between ON and OFF.
CAUTION
If ignition does not occur in 5 seconds,
turn the regulator control knob OFF, wait 5
minutes, then repeat the lighting procedure.
If the burner does not light with the regulator
control knob on, or if the flame goes out after
lighting, gas will continue to flow out of the
burner and could accidentally ignite with risk
of injury.
BURNER FLAME CHECK
Light the burner and adjust the flame with the
regulator control valve. Always check the flame
prior to each use. The air damper mounted on
the burner helps control the amount of primary
air that mixes with the LP gas. A blue flame with
little or no yellow flame will provide the best heat.
Adjust the air damper by turning it clockwise or
counterclockwise to achieve the desired flame.
lococookers.com
OPERATING INSTRUCTIONS
Correct
Yellow flame
Burner holes
Air damper
WHEN BURNER FLAME IS ACCIDENTALLY
EXTINGUISHED:
1. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
2. Turn regulator control knob
counterclockwise to the OFF position.
3. Inspect the hose and make sure
connections are complete. After waiting
5 minutes, restart the appliance following
"INSTRUCTIONS FOR LIGHTING
BURNER."
SHUT DOWN INSTRUCTIONS:
1. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
2. Turn regulator control knob
counterclockwise to the OFF position.
DISCONNECTING REGULATOR FROM LP
TANK:
1. Turn regulator control knob
counterclockwise to the OFF position.
2. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
3. Turn the coupling nut counterclockwise to
loosen the connector. Loosen by hand only.
DO NOT use tools.
4. When disconnected, the regulator should
be hung from the hook attached to the
appliance.
Incorrect
Blue flame
Burner
12

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

LcffLcbfskf

Tabla de contenido