LUBRICATION
Mac Tools
Pneumatic Oil
Always use of an air line lubricator. We recommend the
following Filter–Lubricator–Regulator Unit:
For International– No. C28–C4–FKG0
For USA – No. C28–04–FKG0–28
After each eight hours of operation, unless an air line
lubricator is used, remove Oil Chamber Plug (18) and fill
with Mac Tools Pneumatic Oil.
After each forty–eight hours of operation, or as
experience indicates, inject about 4 cc of Mac Tools
Pneumatic Grease into the Grease Fitting (2).
Model
Type of
Handle
AW434C
pistol
AW434C–2
pistol
H
Tested in accordance with PNEUROP PN8NTC1.2
♦ Tested to ISO8662–7

PLACING TOOL IN SERVICE

Mac Tools
Pneumatic Grease
SPECIFICATIONS
Drive
Impacts
per min.
in.
1/2" sq.
1,200
1/2" sq. with
1,200
extended
anvil
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
H
Recommended
Torque Range
ft–lbs (Nm)
Pressure
25–300
101.8
(34–407)
25–300
101.8
(34–407)
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
♦Vibrations
Sound Level
dB (A)
Power
114.8
114.8
Level
2
m/s
5.2
5.2