MODES
3. MODE 2 (14.4V/25A) 12V Battery
Connect the positive and negative clamps to the terminals of the battery, ensure that the
polarity is correct, then connect the AC power and press the MODE button to select
.
If no other action is taken the charger will start the charging process at 25A±10% The
100% LED will illuminate when the battery is fully charged to 14.4V±0.25V and the charger
will go into maintenance mode automatically and keep the battery fully charged using a
<1.0A trickle current and 1.5A maintenance charge. Under sub zero temperatures, the built
in temperature sensor will automatically change the charging program to apply a higher
voltage (14.7V 25A) to the battery. In this phase the
and
LEDs will illuminate. Once
the battery is fully charged to 14.7V±0.29V the 100% LED will illuminate and the charger will
go into maintenance mode automatically and keep the battery fully charged using a <1.0A
trickle current and 1.5A maintenance charge
3.1 MODE 2.1 (14.4V/25A) 12V AGM Battery
Charging AGM Batteries: AGM batteries must be charged at a higher voltage during
normal conditions. To charge an AGM battery connect the positive and negative clamps
to the terminals of the battery, ensure that the polarity is correct, then press the MODE
button until both
and
are illuminated. If no further action is taken the charger will
automatically start to charge with a current of 25A±10%.at 14.7V. Once the battery is fully
charged to 14.7V±0.29V the charger will go into maintenance mode automatically and keep
the battery fully charged using a <1.0A trickle current and 1.5A maintenance charge.
4. MODE 3 13.6V SUPPLY (13.6V/5.0A)
Connect the positive and negative clamps to the terminals of the battery, ensure that the
polarity is correct, then connect the AC power and hold the MODE button for more than
3 seconds. The
LED will illuminate, and the charger will start the supply program at
13.6V±0.5V constant voltage and 5A±10% constant current. If the voltage drops to 12.0V or
below, the charger will automatically cut off and return to standby mode.
5. MODE 4 16V boost (16V/1.5A) 12V battery only
This mode is used to recondition batteries with a capacity from 50-450Ah under normal
conditions. Warning! The high voltage applied in this mode may cause some water loss, for
optimal results the battery must be disconnected from the vehicle. Connect the positive
and negative clamps to the terminals of the battery, ensure that the polarity is correct,
then connect the AC power and press the MODE button to select
. If no other action
is taken the charger will then start the reconditioning program at 16.5V±0.5V and 1.5A±0.5A.
If the battery is deeply discharged and sulphated the reconditioning program may continue
for up to 4 hours at which point if the battery is not able to reach 13.6V the process will
terminate. If the battery reaches 13.6V then the charger will automatically switch to the
12V charging mode.