OPERATING INSTRUCTIONS
Please read these instructions carefully before using the smart charger.
1. Before attempting to charge a battery, ensure that the terminals are clean. Remove any
corrosion if present and make sure that any of the removed materiel does not contact the
eyes.
2. Ensure that the area around the battery is well ventilated as explosive gasses may
be released during charging. There must be no sources of ignition, sparking wires, open
flames or other anywhere near the battery.
3. If the battery is of the AutoFill type, manufactured by Dagenite or Exide for example, the
glass halls and long filler cap must be left in place during charging.
4. Connect the clamps in the following order
a. First connect the positive clamp (red color) to the positive terminal post.
b. Second connect the negative clamp (black color) to the negative terminal post or to the
chassis remote from the battery and fuel line.
5. Connect the charger to the mains supply, it will turn on, detect the battery voltage, and
start the charging process automatically. If the clamps are incorrectly connected the fault
indicator will illuminate, repeat step 4 correctly.
6. If a mode other than charging is required, press the mode button until the desired mode
is selected. Note: to select the 13.6V continuous supply mode the mode button must be
held for more than 3 seconds when the clamps are not connected to the battery Warning!
Reverse polarity protection is disabled in this mode.
7. If a battery is not fully charged after a maximum of 75 hours, the charger must be
disconnected manually.
8. When the charger is no longer needed disconnect the battery charger from the mains
supply then remove the chassis or negative post connection and finally the positive post
connection. Store the charger safely.
ABNORMALITY PROTECTION FEATURE
If the charger remains in bulk mode for more than 41 hours (416Ah cut-off) then the fault
indicator will illuminate. As with other failure conditions, all other LDS will flash at a 5hz
interval and the charger will output no current. This prevents any damage to the battery.
HSF requirement –RoHS, REACH, 16PAHs<200ppm
Safety requirement –EN60335-2-29, EN60335-1, EN62233 standard for Safety, EN55014-1,
EN55014-2, EN61000-3-2, EN61000-3-3 Standard for EMC test without loading terminal
test.

WARRANTY INFORMATION:

The warranty of this unit depends on the conditions granted by your retailer. The
manufacturer shall have no liability whatsoever at any time for any warranty, personal
injury or property damage. Transport is never included.
Please dispose of the packaging in a responsible manner. It should be recycled by
your local amenity or placed in appropriate recycling bins. Never dispose of electrical
equipment or batteries in your domestic waste. Have them recycled by your retailer or
your local amenity.