TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Monitor light control to verify that the lights come on
at night and turn off during the day.
Adjust lamp holders as needed.
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
SYMPTOM
Lights will not come on.
Lights stay on continuously. Light control is mounted in a dark
Lights flash on and off.
598-1253-00
All manuals and user guides at all-guides.com

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
1. Light switch is turned off.
2. Floodlight is loose or burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a
new installation.
location.
1. Light may be leaking through the
floodlamp reflectors.
2. Light control may be sensing shad-
ows.
SPECIFICATIONS
Electrical Load............ Up to 300 Watt Maximum
Power Requirements .. 120 VAC, 60 Hz
Operating Modes ........ Dusk to Dawn
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.
SOLUTION
1. Turn light switch on.
2. Check floodlight and replace if
burned out.
3. Replace fuse or turn circuit breaker
on.
4. Recheck after dark.
5. Verify wiring is correct.
Relocate light control to an area that
receives more light.
1. Replace the lamps with new high
quality PAR 38 lamps.
2. Relocate light control to an area
away from shadows.
3
Incandescent [Up to 150 Watt
maximum each lamp holder.]