Controlling Non-Motion Sensing
Fixtures
❒
When wiring to additional standard fixture
only: Strip the motion sensor's red wire and
connect to the standard light's black wire.
Connect all white wires together. Total fixture
ratings must not exceed 1000 Watts (8.3 A).
NOTE: All wiring between fixtures should be run
in accordance with the National Electrical
Code (Canadian Electrical Code in Canada)
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.
598-1187-02
All manuals and user guides at all-guides.com
BLACK from
Switch to
BLACK from
JourneyMan
WHITE from Line
to WHITE from
JourneyMan
®
Wiring to a Motion Light & Standard Fixture
❒
This fixture is provided with a sensor rated
for 1000 Watts. Since the fixture is only rated
300 Watts, 700 Watts of additional load may
be controlled by this sensor.
❒
When determining what a fixture is rated for,
do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.
❒
Once you have selected the fixtures to be con-
nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100 Watts, 150 Watts, and 75
Watts respectively, you have a total load of 325
Watts.
RED from
®
JourneyMan
®
to BLACK from
Fixture
WHITE from Line
to WHITE from
Fixture