IPC MicroTimer Manual Del Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Technisch manual
IPC MicroTimer
Control diagram:
Operation in general
The timer starts with the pre-time. During the pre-time, the duration of the main-time will blink in the
display. The duration of the main-time can be limited during the pre-time by activating the Stop timer
button. The pre-time is programmable from 0 up to 255 minutes. The pre-time can be skipped by means
of the quick start function by activating the Start / Pause button. The main-time will follow automatically
after the pre-time. During the main-time the remaining time will appear on the display. The main-time is
programmable from 0 up to 2550 minutes.
The main-time can temporarily be interrupted by activating the Start / Pause button. The post-time will
follow automatically the main-time and is programmable from 0 up to 255 minutes. During the main-time
both relays are active, during the pre-time and the post-time, only relay 2 is active. During the post-time,
the message "CL" (cool) will appear in the display. The timer can be stopped by pushing the Stop
button. If the Stop button is activated during the main-time, the post-time will automatically be initiated.
When the Stop button is activated during the pre-time, the main-time will be shortened with 1 minute.
- S software version
- During the prior time, contact 2 is closed.
During the prior time, the display blinks with the
value of the main time.
- During the main time, both contacts are closed
(relay 1 & 2). The display shows the remaining
time. The Pause key can be used for temporary
interruption of the main time.
- During the post time, only contact 2 is closed.
During the post time the display shows "CL".
–P software version
- During the prior time, relay signals will not be
confirmed. During the prior time, the set value of
the main time will be displayed blinking.
- When the main time begins, MicroTimer will
send a pulse to relay. The remaining time of the
main time will be shown on the display.
- When the post time begins, MicroTimer will
send a pulse to relay 2. The display will show
"CL".
Relay control diagram:
–S software version,
(signal output)
Timer
Relay 1
Stand-by
Off
Prior time
Off
Main time
On
Pause
Off
Post time
Off
Technisch manual
IPC MicroTimer
Ontwikkelingsspecificaties, wijzigingen voorbehouden
–P software version
(pulse output)
Relay 2
Relay 1
Off
Off
On
Pulse
On
Off
On
Off
On
Off
IPC Systems B.V.
Prior time
Main time
Post time
Standard display
Relay 2
Off
- (hyphen)
Off
Main time blinking.
Off
Remaining main time
Off
Main time blinking.
Pulse
CL
3
Pause
Pagina
12
Versie
1.3
Datum
14-03-'02

Publicidad

Tabla de contenido
loading