_______________________________________________________________________________
100MHz
Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80%
duty cycle and > 100kHz.
Frequency
40.00Hz-10KHz
(electrical)
Sensitivity:1Vrms
Duty Cycle
0.1 to 99.90%
Temp
-50 to 1200qC
(type-K)
-58 to 2192qF
4-20mA%
-25 to 125%
0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125%
Note: Accuracy specifications consist of two elements:
x (% reading) – This is the accuracy of the measurement circuit.
x (+ digits) – This is the accuracy of the analog to digital converter.
Store capacitance
2000
Enclosure
Double molded, waterproof
Shock (Drop Test)
6.5 feet (2 meters)
Diode Test
Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Continuity Check
Audible signal will sound if the resistance is less than 35: (approx.), test current <0.35mA
PEAK
Captures peaks >1ms
©Copyright Abacanto Digital SA.
0.01MHz
0.01Hz - 0.001KHz
0.01%
Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz
0.1qC
0.1qF
0.01%
Manual de usuario AD9929
AD Instruments
Not specified
r (1.2% reading + 2 digits)
r(1.0% reading + 2.5°C)
r(1.0% reading +4.5°F)
(probe accuracy not included)
±50 digits
r (0.5% reading)
49