Dometic Smart D Instrucciones De Montaje Y De Uso página 48

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91
All manuals and user guides at all-guides.com
Connecting and installing Dometic Smart D
No. in
fig. 9,
Description
page 7
2
X1 – X6
3
CI
4
X11 – X16
48
Explanation
Analogue outputs for connecting up to six devices
(X1 – X4: cable cross section ≥ 1.5 mm²)
(X5 – X6: cable cross section ≥ 2.5 mm²)
X1 – X4: max. 6 A
X5 – X6: max. 18 A
The permanent power monitoring of each output
ensures these are switched off in the event of a short
circuit.
The individual outputs are programmed with a prede-
fined current threshold so that they are disconnected if
the programmed current is exceeded. An alarm can
also be emitted if this is the case.
In order to reset the outputs where the excess current
has occurred, the system must be switched off using
the ON/OFF button (fig. a 1, page 8).
Outputs X1 to X5 are both analogue and digital with
pulse width modulation (PWM).
Output X6 is analogue.
Connection to the CI Bus
(cable cross section 0.5 – 1 mm²)
Inputs
(cable cross section 0.5 – 1 mm²)
X11 – X15: digital
X16: digital and analogue
The digital signal has a negative logic (with a minus
connection, a TRUE logic state is produced). If the
inputs are to be connected with a positive signal, then a
converter relay must be used for this!
Dometic Smart D
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido