Replacing The Fuse; Cleaning And Caring For The Inverter - Dometic GROUP WAECO PerfectPower PP152 Instrucciones De Montaje Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40

Replacing the fuse

Observe the following when using the device
If the battery voltage falls below 10.8 V (PP152/PP402/PP602) or 21.5 V
(PP154/PP404/PP604) during operation, a warning tone sounds. If the
battery voltage falls further, the inverter switches off and the red error LED
(fig. 1 2, page 2) lights up.
If the inverter overheats, it switches off – the red error LED (fig. 1 2, page 2)
lights up.
➤ If this happens, switch the inverter off with the switch.
When it cools down, you can use the inverter again.
When operating the inverter at a high load for lengthy periods, it is advisable
to start the engine in order to recharge the vehicle battery.
You can operate the inverter with the engine running or switched off.
However, do not start the engine while the inverter is switched on, since the
power supply to the cigarette lighter is disconnected during ignition.
8
Replacing the fuse
This is how to change the fuse of the inverter:
➤ Take the defective fuse (fig. 2 3, page 3) out of the holder on the back.
➤ Put in a new fuse of the same rating.
9

Cleaning and caring for the inverter

NOTICE!
A
Do not use sharp or hard objects or cleaning agents for cleaning as
these may damage the product.
➤ Occasionally clean the product with a damp cloth.
24
All manuals and user guides at all-guides.com
PerfectPower
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido