Technical Datas - CLAS OH 9040 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OH 9040
Oil leaks from the succion pump
1. Check the quantity of oil in the tank, (see the "Oil level check"). If too much oil has been put in the jack, it will
stop leaking very soon.
2. Check that the jack has been used observing the conditions listed previously, i.e. horizontally and not slanted.
If the jack has been turned upside down or tipped over, it will stop leaking very soon.
The pistons are very slow to move up
- Check that the tap, located between the tank and motor pump is open.
- If the jack malfunctions when moving up, check the spring.

TECHNICAL DATAS

Air pressure: 8 > 10 bar
Working temperature: -20°C > +50°C
Air consumption: 400nl/min
Compatibles oils: ATF Dexron IID
Pneumatics system pipes: Rilsan ø 6x4mm
Weight: 39Kg
Max. stroke: 150mm
1st stage capacity: 40T
2nd stage capacity: 20T
AIR HYDRAULIC JACK 20/40T
Aerial Noise
Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R
1680 - 1970. Instrument: LARSON DAVIS 800 B
PRECISION ANALYSER PHONOMETER in conformity
with the standards IEC 804 E 651 class 1 set with a
Larson Davis Ca 250 114/b 250 Hz calibrator before
and at the end of the measurements.
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
F (mm)
G (mm)
H (mm)
525
270
150
150
300
206
1400
1320