Controls And Indicators - Allmatic A1H-U Manual De Instrucciones

Ocultar thumbs Ver también para A1H-U:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Controls and Indicators

SENSITIVITY SETTING
Sensitivity
DETECT / FREQUENCY COUNT
Presence detected
No presence
Frequency count
POWER / LOOP FAULT INDICATOR
Normal operation
Shorted loop
Open loop
Abrupt change (>20%)
Previous loop fault
ULTRAMETER™ DISPLAY
Indicates sensitivity setting required to detect vehicle
FREQUENCY COUNT / RESET
Press to start frequency count, re-initializes after count
AUTOMATIC SENSITIVITY BOOST
ASB enabled
PRESENCE
NORMAL (5 min.)
INFINITE
DELAY (2 seconds)
DELAY
SPARE (not used)
FAIL SAFE / SECURE
Fail Secure
Fail Safe
FREQUENCY SETTINGS
FREQUENCY
Low
Medium low
Medium high
High
A1H-U
6-1621238 rev.0 09/12/2013
All manuals and user guides at all-guides.com
Position 0.......9
Low..........high
Red LED
on
off
flashing
Green LED
on
1 fast flash
2 fast flashes
3 fast flashes
2 slow flashes
DIP switch position 1
on
DIP switch position 2
on
off
DIP switch position 3
on
5
4
DIP switch position 6
on
off
DIP switch position
7
8
on
on
on
off
off
on
off
off
5