Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
• Ensure that no moisture can enter the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.

Remedy of faults

Issue
Lamp does not light up
Reduced performance/ Dimming
Water in the lamp body
Light is flickering

Wear parts

Bulbs are wearing parts and are excluded from the warranty.
Repair
Neither the transformer nor the spotlight can be repaired in the event of damage to the cables or the housing and must,
therefore, be replaced.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
10
11634-02-14_GA_LunAqua 2-12V.pdf10 10
All manuals and user guides at all-guides.com
Cause
− device does not receive power
− bulb defective
− bulb contacts have corroded
− glass lens is dirty
− gasket is defective / not installed correctly
− bulb contacts corroded
Remedy
− check power connection
− change bulb
− clean contacts
− clean lens
− check gasket and replace, if necessary
− clean contacts