PROBLEM
No power
Internal temperature not cold enough
Appliance runs continuously
Alarm sounding and "HI" on the display panel
Condensation on the cabinet or door
Alarm sounding and "LO" or "CL" on the display
panel
Silhouette Consumer Care: 1-844-455-6097
9
POSSIBLE CAUSE
• A fuse may be blown or the circuit breaker
tripped
• Plug not fully inserted into the wall outlet
• Door is not shut properly or opened excessively
• Exhaust vent is obstructed
• Recently added a large quantity of warm bottles
to the cabinet
• Close proximity to heat source or direct sunlight
• Ambient temperature or humidity is very high
• Possible system leak, evaporator fan failure or
compressor failure
• Door is not shut properly or opened excessively
• Ambient temperature or humidity is very high
• Ambient temperature is excessively low
• Sensor failure
• Evaporator temperature is too low