Product Description; Technical Data - Vanderbilt SPCY521 Manual De Instrucciones

Publicidad

English – Installation Instructions
Attention: When using this product in conjunction with the SPCK52x keypad,
the device shall only be connected to power supplies compliant to EN60950-
1, chapter 2.5 ("limited power source").
Risk of damage to the device
When using this product in conjunction with the SPCK52x keypad, follow
these guidelines:
Use the device only indoors and in dry environments.
Do not expose it to dripping or splashing water.

Product Description

The SPCY521 Metal Back Box allows the SPCK520/521 keypads to be recessed
into a wall ensuring a neat and elegant appearance. The SPCY521 Metal Back
Box is intended for use with the SPCY520 product. These products are designed
to accommodate back tamper support for the keypads.
Fig. 1: Flush Mount Assembly with Metal Back Box Installation
Keypad front cover
1
Keypad base
2
Flush mount box
3
Metal back box
4
Fig. 2: Metal Back Box
Mounting screw holes
1
Grips
2
Cable breakouts
3
Fig. 3: Metal Back Box – Screw Mounts
Mounting holes for the SPCY520 flush mount box
1
Screw holes for fixing metal back box to the wall
2
Mounting holes for keypad back tamper plate
3
Fig. 4: Flush Mount Box - Screw Mounts
Fixing screw mounts for keypad base
1
Screw holes for fixing flush mount box to metal back box
2
Cable entry points
3
Flush mount box front plate
4
Fig. 5: Compact Keypad with Flush Mount Box and Metal Back Box – Side
View
Flush mount box front plate
1
Keypad front cover
2
Keypad base
3
SPCY520 metal back box
4
Wall
5
Mounting the Flush Mount Metal Back Box
1. Prepare a rectangular recess in a wall larger than the size of the metal back
box.
2. If required, pull out the grips from the side of the metal back box (Fig. 2, item
2) as appropriate to secure tightly.
3. Mark 4 holes at the back or the side of this recess for the fixing screws (Fig. 2,
item 1 and Fig. 3, item 2).
4. Drill the holes and screw the metal back box into the wall.
5. Bring the keypad cables through the cables breakouts and into the metal back
box (Fig. 2, item 3).
Mounting the Flush Mount Box
1. Place the flush mount box into the metal back box
2. Fix the flush mount box to the metal back box via the screw holes on the flush
mount box (Fig. 4, item 2) and the screw mounts on the metal back box (Fig. 3,
item 1).
3. Bring the keypad cables from the metal back box into the flush mount box
through the flush mount box cable entry points (Fig. 4, item 3).
Mounting the Keypad Base Plate with Tamper
1. Insert the keypad base into the flush mount box.
2. Bring the keypad cables through the cable breakouts of the keypad base.
3. Fix the keypad base to the flush mount box via the screw holes on the base
and the screw mounts on the flush mount box (Fig. 4, item 1).
4. Fix the keypad base to the metal back box via the screw holes on the tamper
plate on the base and the screw mounts on the metal back box (Fig. 3, item 3).
The securing screw that is provided with the SPCK52x keypad cannot be
used in conjunction with a flush mount solution.
Closing the Keypad Front Cover
1. Hook the top of the front cover into the securing lugs of the keypad base and
press downward.
2. Press firmly to ensure that the two clips on the base engage with the
corresponding recesses in the front cover.
Removing the Recessed Keypad
A removing tool is provided to enable the keypad front cover to be removed easily
from the flush mount box.
1. Push the two prongs of the tool into the clip openings at the bottom of the flush
mount box (Fig. 6, action 1).
2. When the prongs engage with the clips of the keypad base, push the clips
upward and lever the tool backward (Fig. 6, action 2) until the cover opens.
3. Remove the tool.
4. Lift the cover no higher than about 1 cm to avoid breaking the restraining lugs
at the top of the cover and then pull the cover gently down and away from the
unit.

Technical Data

Mounting
Housing
Dimensions (W x H x D)
Weight
Housing protection/IP rating
Deutsch – Installationsanweisungen
Achtung: Bei der Nutzung dieses Geräts in Verbindung mit dem
Bedienteil SPCK52x darf das Gerät nur an Stromquellen angeschlossen
werden, die der Norm EN 60950-1, Kapitel 2.5 („Stromquelle mit
beschränkter Leistung") entsprechen.
Gefahr von Schäden am Gerät!
Bei der Nutzung dieses Produkts in Verbindung mit dem Bedienteil
SPCK52x müssen folgende Richtlinien beachtet werden:
Das Gerät nur in trockenen Innenräumen verwenden.
Das Gerät weder Tropf- noch Spritzwasser aussetzen.
Produktbeschreibung
Mit der UP-Metall-Einlassdose SPCY521 können die Bedienteile SPCK520/521 in
der Wand versenkt installiert werden, um ein ordentliches und elegantes
Erscheinungsbild zu gewährleisten. Die UP-Metall-Einlassdose SPCY521 ist für
die Verwendung mit dem Produkt SPCY520 vorgesehen. Diese Produkte wurden
für die Aufnahme des rückwärtigen Sabotagekontakts von Bedienteilen entwickelt.
Abb. 1: Bündige Montage mit Installation einer UP-Metall-Einlassdose
Frontplatte des Bedienteils
1
Bedienteilsockel
2
UP-Einbaurahmen
3
UP-Metall-Einlassdose
4
Abb. 2: UP-Metall-Einlassdose
Bohrungen für Befestigungsschrauben
1
Klemmen
2
Kabelausbruchstellen
3
Abb. 3: UP-Metall-Einlassdose – Schraubbefestigungen
Montagelöcher für den UP-Einbaurahmen SPCY520
1
Schraubenbohrungen zur Wandmontage der UP-Metall-Einlassdose
2
Montagelöcher für rückwärtige Sabotageschutzplatte des Bedienteils
3
Abb. 4: UP-Einbaurahmen – Schraubbefestigungen
Schraubbefestigungen für Bedienteilsockel
1
Schraubenlöcher zur Anbringung des UP-Einbaurahmens in der UP-
2
Metall-Einlassdose
Kabeleinführungsöffnungen
3
Frontplatte des UP-Einbaurahmens
4
Abb. 5: Kompakt-Bedienteil mit UP-Einbaurahmen und UP-Metall-
Einlassdose – Seitenansicht
Frontplatte des UP-Einbaurahmens
1
Frontplatte des Bedienteils
2
Bedienteilsockel
3
UP-Metall-Einlassdose SPCY520
4
Wand
5
Montage der UP-Metall-Einlassdose
1. Bereiten Sie eine rechteckige Aussparung in der Wand vor, die größer als die
UP-Metall-Einlassdose ist.
2. Ziehen Sie gegebenenfalls die seitlichen Klemmen der UP-Metall-Einlassdose
heraus (Abb. 2, Element 2), um die Dose sicher zu befestigen.
3. Markieren Sie vier Löcher für die Befestigungsschrauben an der Rückseite
oder Seite der Wandaussparung (Abb. 2, Element 1 und Abb. 3, Element 2).
Flush mounted
Stainless steel SS430
155 x 117 x 29 mm
40 g
IP30

Publicidad

loading