HVAC control
On/Off. Pressing the icon turns the zone in which the thermostat is located on or off.
23.5°
Set-point temperature. Using the - and + signs that appear when you press on the
temperature, you can select the desired set-point temperature, in steps of 0.5°C.
The temperature range permitted in heating mode is: 15-30°C. In cooling mode: 18-30°C. These
vary depending on the level of efficiency (Eco-Adapt) that has been selected on the master
EN
interface.
Efficiency indicator. Depending on the working temperature, the Blueface thermostat
displays a range of colors based on the system's level of efficiency:
Green: very efficient.
Operation mode
This is managed from the master thermostat, press to access the selection menu. The available
modes are as follows:
Stop. The HVAC system remains shut down regardless of the status of the rest of the zones.
In addition, all terminal elements (grilles, dampers, etc.) will be closed.
Cooling. In this operation mode, the system only operates with the AC unit in cooling mode
when any of the zones associated to the system is generating demand (set-point temp. < room
temp.).
Heating. In this operation mode, the system only operates with the AC unit in heating mode
when any of the zones associated to the system is generating demand (set-point temp. > room
temp.).
Ventilation. In this operation mode, the system only operates with the AC unit in ventilation
mode when any of the zones associated to the system is generating demand (set-point temp. <
room temp.).
Dry*. In this operation mode, the system only operates with the AC unit in dry mode,
refreshing the environment and prioritizing the operation to reduce humidity, when any of the
zones is generating demand (set-point temp. < room temp.).
*Note: This mode is ideal for days when humidity is high: it reduces the occurrence of water
particles on the grilles.

Eco-Adapt function

This sets your system's level of energy efficiency and adapts the temperatures to progressively
more efficient values, establishing limits according to the degree of energy savings selected:
Off. The temperature range is the range permitted by the system.
Manual. Sets the temperature limits in the zones according to those defined in the master
thermostat.
4
Yellow: efficient.
Orange: inefficient.
Red: very inefficient.