3. Installation
1. Fix the mounting nut (7) of the regulator on the thread of the CO
2. Adjust the pressure regulator and secure the mounting nut (7) firmly. Take care that the neck
of the pressure regulator won't be separated from the body since otherwise CO
3. Connect the CO
-tube to the corresponding fitting (4). Remove the nut (5) and put it on the
2
hose. The hose is then fixed on the fitting with nut.
4. Adjustment
1. The needle valve (3) is only opened a bit for pre-adjustment.
2. Open the valve at the CO
pressure gauge shows 60 - 70 bar, the working pressure gauge approx. 1.5 bar.
3. Open the needle valve slowly until the desired number of bubbles is reached in the bubble
counter.
Bubble counter: The exact control of the flow rate is only possible if a bubble counter is used. We
recommend the bubble counter of Aqua Medic's CO
can only be controlled at the CO
5. Safety tips
-
Never separate a stationary pressure regulator from a CO
the bottle valve, release pressure from the pressure regulator and unscrew the pressure
regulator.
-
Protect the CO
bottle from heating.
2
-
Always operate the CO
-
Never dismantle the pressure regulator.
6. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid.
Proof of Purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase. This warranty may not apply if any model
or production number has been altered, deleted or removed, unauthorised persons or organisations
have executed repairs, modifications or alterations, or damage is caused by accident, misuse or
neglect. Please note that the product is not defective under the terms of this Warranty where the
product, or any of its component parts, was not originally designed and / or manufactured for the
market in which it is used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
Current manuals are available for download at www.aqua-medic.de.
bottle (four full turns) and close the needle valve. Now, the bottle
2
reactor.
2
bottle standing upright and fix it well (to the wall).
2
- Technical changes reserved - 08/2017
bottle (hand tight).
2
program. Without bubble counter, adjustion
2
bottle if it is under pressure. Close
2
will escape!
2
4