Description
Battery voltage
(The battery-saver device has cut in. Voltage has fallen below the value of 21.5 V)
Fan over current cut-out
(The condenser or evaporator fan overloads the central control unit above the limited allowed. Possible cause:
short circuit or blockage of fan rotation.)
Compressor locked
(The rotor is locked or the pressure inside the cooling circuit is too high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the compressor cannot maintain the minimum rotation speed.)
High temperature on the central control unit
(If the cooling circuit is overloaded or the ambient temperature is high, the central control unit signals this
situation.)
Communication error
(There is no communication between the display and the central control unit.)
Temperature probe
(If the probe short-circuits or is not connected, the system stops.)
Tilt
(The system shut-down device installed to operate in the event of tilting has cut in. N.B.: The device only cuts
in if the evaporator is installed transversally to the direction in which the vehicle travels.)
The remote control regulates both the conditioning function and the fan function.
Using the remote control it is possible to:
- Switch the system on and off
- Regulate the temperature
- Regulate the fan speed
- Engage the TURBO function
- Modify the TIMER function


ERRORS SHOWN ON THE DISPLAY (AC / FAN)
REMOTE CONTROL
SLEEPING WELL 1000
SLEEPING WELL 1000
Message
Symbol
E1
E2
E3
E4
E5
E6
E7
E8
Sleeping Well 1000_01_05/2007
Sleeping Well 1000_01_05/2007