ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
6.For typical under counter installation of an electric built-in oven see Figure below.
Only certain cooktop models may be installed over certain
built-in electric oven models. Approved cooktops and built-
in ovens are listed by the MFG ID number and product
code (see the insert sheet included in the literature pack-
age and cooktop installation instructions for dimensions).
To reduce the risk of
personal injury and
tipping of the wall
oven, the wall oven
must be secured to
the cabinet (s) by
mounting brackets.
208/240 Volt junction box
for built-in oven.
* If no cooktop is installed directly over
the oven unit, 5" (12.7 cm) maximum
is allowed above the floor.
Figure 9- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
All manuals and user guides at all-guides.com
(and Optional Electric or Gas Cooktop Combination)
Approx. 3"
(7.5 cm)
G
4 1/2" (11.5 cm) Max.*
27" (68.6 cm)
Wall Oven
30" (76.2 cm)
Wall Oven
WITH AN ELECTRIC COOKTOP MOUNTED ABOVE
Cabinet side filler panels are
necessary to isolate the unit
from adjoining cabinets. Cabinet
side filler height should allow for
installation of approved cooktop
models
F
Use 3/4" (1.9 cm) plywood, installed on two
runners, flush with toe plate. Base must be
capable of supporting 150 pounds (68 kg)
for 27" models and 200 pounds (90 kg) for
30" models.
Cut an opening in wood base minimum 9" x 9"
(23 X 23 cm), 2" (5 cm) from left side filler
panel, to route armoured cable to junction box.

CUTOUT DIMENSIONS

F.WIDTH
24
7
/
" (63.2 cm) Min.
8
23½" (59.7 cm) Min.
25¼" (64.1 cm) Max.
28½" (72.4 cm) Min.
23½" (59.7 cm) Min.
29" (73.7 cm) Max.
7
36" Min.
(91.4 cm) Min.
H
G.DEPTH
H.HEIGHT
27¼" (69.2 cm) Min.
5
28
/
" (72.7 cm) Max.
8
27¼" (69.2 cm) Min.
28
5
/
" (72.7 cm) Max.
8