RECOMMENDED COMPRESSED AIR SYSTEM
No.
1
Air tool
2
Air hose
3
Quick coupling
Oiler
4
(for tools with motor)
5
Pressure reducer
MAINTENANCE
• Air tools should be operated on air systems that have an automatic oiler.
When using air systems that do not have an automatic oiler, air tools
must be regularly added oil to the air tool via the air connection.
• Before first use, add 4 to 5 drops of air device oil to the air connection of
the device.
• Do not use engine or gear oil, to oil pneumatic tools; only use oil for
pneumatic tools.
• Drain the compressed air system before each use. Water in the air lines
leads to a loss of performance and damage to the air tool.
• Clean or replace the air filter on the compressor at the prescribed
intervals.
• Only operate the air tool with the maximum pressure specified in the
chapter "Technical data".
OVERVIEW
1
Guide handle
2
Polishing disc
3
Locking lever
4
Trigger lever
5
Device handle
6
Compressed air inlet
7
Air outlet
OPERATING
1. Remove the air cap from the tool air inlet (6).
2. Install the air inlet nipple.
3. Lubricate the tool before operating. (See chapter "MAINTENANCE" oiling instructions.)
4. Connect the air supply hose to the tool.
5. Set the working pressure to 6.2 bar (90 psi).
6. Push the locking lever forward and press the trigger lever. The tool starts to work.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Designation
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
No.
Designation
6
Drainage/filtering unit
7
Drainage valve
8
Shut-off valve
9
Dryer/filter unit
10
Compressor
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed