All manuals and user guides at all-guides.com
in this way it is possible to select one or more functions by clicking with the mouse on the relevant box;
here we list a description of the single functions that can be implemented by modifying the CFG TRAN-
SPONDER parameter:
Enable Relay: when enabled it permits activating the relay inside the device, otherwise even if the
reader acknowledges a transponder key from among the ones stored in memory it will not activate its
internal relay;
TxTrspCodeMem: enables the transmission of a standard packet with the data of the key read and
acknowledged from among the ones stored in memory and the associated position of the key in the
reader memory (88TK or 800T); (parameter planned for future applications);
TxTrspCodeNoMem: enables the transmission of a standard packet with the data of the key read
although not acknowledged from among the ones stored in memory and the associated position of the
key in the reader memory (88TK or 800T); (parameter planned for future applications);
TxPacket(DGB) : enables the transmission of a DigiBUS standard packet with the following data: tran-
smission packet identifier = DigiBUS identifier and the DigiBUS command transmitted is the one set in
the DIGIBUS COMMAND field
ToggleRelè: when the Enable Relay parameter is enabled it permits activating the relay inside the
reader (88TK or 800T) in bistable mode (TOGGLE): acknowledgment of a key activates the relay per-
manently, another acknowledgment deactivates the relay;
TxPacket (generic): when the TxPacket(DGB) parameter is enabled it permits the transmission of a
general packet, not necessarily DigiBUS (this packet is retrieved from fields in the reader memory
(88TK or 800T); this command takes a higher priority than the TxPacket (liftDGB) parameter; (para-
meter planned for future applications);
TxPacket (liftDGB): when the TxPacket(DGB) parameter is enabled it permits the transmission of a
DigiBUS standard packet with the following data: transmission packet identifier = DigiBUS identifier +
Additional value (possible values: 1... 63 )
(typical application required: send a command to a receiver to activate a lift at the floor) and the tran-
smitted DigiBUS command is the one set in the DIGIBUS COMMAND field; this command takes a
lower priority than the TxPacket (generic) parameter;
Note on the TxPacket (liftDGB) parameter: As stated in the description of the parameter, using this
function requires reading an additional value in the reader memory (88TK or 800T) that can be modi-
fied via the generic field Info1 of the DataOrganiser software tool;
17