Read, understand, and follow all safety information contained in these instructions
prior to installation and use of the Filtrete™ Standard and Professional Water
Filtration Systems. Retain these instructions for future reference.
Intended use:
The Filtrete Standard and Professional Water Filtration Systems are intended for use in fi ltering
drinking water in homes and have not been evaluated for other uses. These systems are
typically installed under a sink where fi ltered drinking water is desired, and must be installed,
operated and maintained as specifi ed in the installation and use instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
CAUTION
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Only the Professional Water Filtration
System (3US-PS01) is certifi ed for cyst reduction and may be used on disinfected water
that may contain fi lterable cysts. EPA Establishment #070595-CT-001.
To reduce the risk associated with a hazardous voltage:
• Do not install near electric wiring or piping which may be in the path of a drilling tool when
selecting the position to mount the fi lter bracket.
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system;
• Comply with all state or local plumbing codes;
• Install on cold water lines only;
• Protect fi lter from freezing. Drain fi lter when room temperature drops below 40°F (4.4°C);
• Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds
80 psi, you must install a pressure limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure;
• Do not install where water hammer conditions may occur. If water hammer conditions
exist you must install a water hammer arrester. Contact a plumbing professional if you are
uncertain how to check for this condition;
• Do not install on hot water supply lines. The maximum operating water temperature of
this fi lter system is 100°F (38°C);
• The disposable fi lter cartridge must be replaced every six months, at the rated capacity
or if a noticeable reduction in fl ow rate occurs.
• Do not install near water pipes which will be in path of a drilling tool when selecting the
position to mount the bracket;
• Mount fi lter in such a position as to prevent it from being struck by other items used in the
area of installation (waste baskets, etc.);
• Ensure all tubing and fi ttings are secure and free of leaks;
• Do not install in direct sunlight.
IMPORTANT NOTES
• SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off.
• Failure to follow instructions will void warranty.
• Allow a minimum of 2" (5 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
SAFETY INFORMATION
Indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided,
may result in property damage.
WARNING
CAUTION