Maintenance
The unit echoes.
When operation is started or the opera-
tion mode is changed, an unusual noise is
heard in main unit.
There are some stains left in the draina-
ge tank.
The unit only can run in laundry
mode and it is ineffective
to press mode switch.
The fan is running and the compressor
does not work.
APÉNDIX

Electric Schematic Diagram

If the unit is used in a room with wood flooring or in a
small room, it may echo.
The refrigerant may take some sound until circulation
stabilizes.
This is water left from the dehumidifying test conducted
at the factory, it does not indicate a problem.
When the temperature of the room is above 35ºC or
below 15ºC the protection device is actuated, so that the
unit only can run in LAUNDRY mode (the fan speed is
high).
If the unit is started within 3 minutes after the unit stops,
the protection device is actuated, so that the compressor
is started automatically after a delay of 3 minutes; or the
automatic defrosting operation is activated and the com-
pressor stops.
59