Dataline surge protector
Parafoudre pour ligne de données
Proteccion para lineas datos
Überspannungsschutz für Datentechnik
Protezione per linee dati
Protetor de Surto para linha de dados.
6
5
1
2
RED=to replace
4
RED=to replace
3
DLATS1
DLATS1/R
DLATS-P24DC
DLAWTS1
DLAWTS1/R
DLATS1-P24DC
Wiring
1 Pair
DLATS1, DLAWTS1
Surge Protector
or DLATS1/R, DLAWTS1/R
Pair (1a - 2a)
1
V+
2
V -
3
4
DIN rail
Pair (1b - 2b)
NOTE :
DLATS1, DLAWTS1 and DLATS1/R,
DLAWTS1/R surge protectors must be
connected to the bonding network through
one of the 3 connection points.
Technical Data
2000 m max.
6500 ft max.
-40/+85°C max.
-40/+185°F max.
IP20
indoor use only
Humidity range
5% to 95%
Max. DC operating voltage (Uc)
8 V
15 V
28 V
53 V
170 V
24 V (DC power)
Connection to Network
Screw terminal
Spring terminal
Characteristics
Max. line current I
L
Current consumption (per module)
Remote signaling
* or DLAWTS1-xxx
** or DLAWTS1-xxx/R
*** or DLATS1-P24DC
Power module
Power module
DLATS1, DLAWTS1
(DLATS1-P24DC)
or DLATS1/R, DLAWTS1/R
-
+
Voltage supply range for
power input : 20 to 28Vdc
Connector- 4pin
Pin1 & 2, 20 to 28Vdc power
1
V+
2
V -
Pin3 & 4, Relay switch.
3
Normal condition: open
4
Abnormal condition: close
Indicator, Green : power on
11
12
Remote signal relay output
14
2
11
12
: Normally close NO
&
1
3
: Normally open NC
11
&
14
12
Connection of
11
monitoring device
14
Installation
P/N
DLATS-P24DC
0.5-2,5 mm²
#20-13 AWG
1
DLATS1-xxx, DLAWTS1-xxx
SCREW TERMINAL
CONNECTION
300 mA
1-power module & 4-DLATS1 1or 4-DLAWTS1
< 19 mA
Yes
R-BUS 25P to connect 1-power module & 24-DLATS1 or 24-DLAWTS1 (max. number of device which can be connected)
Connection between power module and SPD modules by ribbon wire (R_BUSxxP)
modules
24V+
1
V+
1
1
V+
1
V+
24V -
2
V -
2
2
V -
2
V -
3
3
3
3
4
4
4
4
R-BUS 5P to connect
1-power module & 4-DLATS1 1or 4-DLAWTS1
R-BUS 25P to connect 1-power module & 24-DLATS1 or 24-DLAWTS1 (max. number of device which can be connected)
R-BUS 49P to connect 1-power module & 48-DLATS1 (max. number of DLATS which can be connected)
Assembly of
2
DLATS1-xxx or DLAWTS1-xxx
+ R-BUS 25P
5 mm
for 4, 9 or 24 surge protected lines
0.2 in
5 mm
0.2 in
4
0.5 Nm
4.4 Lb-In
#20-13 AWG
3
0.5-2.5 mm²
Maximum number of DLATS1 and DLAWTS1 which can be connected on one side :
1-power module with 24-DLATS1 or 24-DLAWTS1
R-BUS 5P to connect
R-BUS 10P to connect
1-power module & 9-DLATS1 or 9-DLAWTS1
DLATS1-P24DC
-
+
1
24V+
1
V+
1
V+
1
2
24V -
2
V -
2
V -
2
3
3
3
3
4
4
4
4
R-BUS 10P to connect
1-power module & 9-DLATS1 or 9-DLAWTS1
5 mm
0.5-4 mm²
0.2 in
#20-11 AWG
3
5 mm
0.2 in
5
6
2
1
2
Push
1
4
3
#20-11 AWG
4
0.5-4 mm²
5
Push
DLATS1-xxx/R, DLAWTS1-xxx/R
SPRING CONTACT
CONNECTION
24V+
1
V+
1
V+
1
1
V+
1
V+
24V -
2
V -
2
V -
2
2
V -
2
V -
3
3
3
3
3
4
4
4
4
4

Publicidad

loading

Resumen de contenidos para Citel DLATS1-170 Serie

  • Página 1 Installation Technical Data Assembly of N200715 5 mm 2000 m max. DLATS-P24DC DLATS1-xxx or DLAWTS1-xxx 0.5-4 mm² 6500 ft max. 0.2 in + R-BUS 25P 5 mm #20-11 AWG for 4, 9 or 24 surge protected lines INSTALLATION INSTRUCTIONS - NOTICE D'INSTALLATION 0.5-2,5 mm²...
  • Página 2 Installation N200715 DLATS1-P24DC 5 mm Assembly of 0.5-2,5 mm² 0.2 in DLATS1-xxx, or DLAWTS1-xxx INSTALLATION INSTRUCTIONS - NOTICE D'INSTALLATION + R-BUS 49P #20-13 AWG NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE for 48 surge protected lines 5 mm ISTRUZIONI PER L'INSTALLAZIONE 0.2 in INSTRUCOES DE INSTALACAO - MONTÁŽNÍ...
  • Página 3 SAFETY INSTRUCTIONS BEZPEČNOSTNÍ POKYNY VARNOSTA NAVODILA www.citel.fr 安全须知 www.citel.de CONSIGNES DE SECURITE VEILIGHEIDSVOORSCHRIFTEN www.citel.us SICHERHEITSHINWEISE AVISOS IMPORTANTES BEZPEČNOSTNÉ POKYNY www.citel.com.cn ADVERTENCIA DE SEGURIDAD SIKKERHEDSANVISNINGER www.citel.ru 2, rue Troyon 92316 www.citel.in AVVERTENZE IMPORTANTI WSKAZÓWKI BEZPIECZEŃSTWA SÄKERHETSANVISNINGAR Sèvres CEDEX France ATTENTION !

Este manual también es adecuado para:

Dlats1-48d3 serieDlats1-24d3 serieDlats1-12d3 serieDlats1-06d3 seriePlats 1-170/r seriePlats1-48p3/r serie ... Mostrar todo