9. This unit is equipped with a 3-conductor power cord and 3-prong grounding
plug. It must be connected to a correspondingly grounded power outlet
protected by a class A Ground Fault Circuit Interrupter (GFCI) to prevent
electric shock hazard. (Trip current < 6 mA)
10. Should you encounter any problems within the first year of purchase, contact
the BIO-CIRCLE™ Technical support center. See page 17
INTRODUCTION
Your BIO-CIRCLE™ Parts Cleaning System is precision built to meet the highest
industrial standards. For maximum performance and longest life, follow the
operating instructions and maintenance procedures outlined in this manual.
This unit is CSA certified for both Canada and USA. It is supplied
with a 3-conductor power cord and a 3-prong grounded plug. It must
be connected to a grounded receptacle protected by a Class A
Ground Fault Circuit Interrupter (GFCI).
VOLTAGE
Before connecting this unit, check that the voltage shown on the rating plate is
the same as that of the power source.
Operating this unit on a voltage other than specified on its rating plate may result
in personal injury to the user and damage to the unit.
EXTENSION CORD
The use of an extension cord is not recommended, however if one must be used,
use one that is heavy enough for the power requirement of the unit. Extension
cords of inadequate wire size cause a serious drop in voltage and possible
electrical component damage.
To limit line voltage drop to a safe level, refer to the following table:
Length in Meters
Length in Feet
Wire Size AWG
Note: Extension cords that are used outdoors must be approved for outdoor use.
All manuals and user guides at all-guides.com
8
25
14
4
15
23
50
75
14
12
30
100
10