Charging Stages - GOAL ZERO 10 AMP Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
After going into charging process, the LCD displays the charging statues as below:
Press VOLT / AMP button in sequence, the LCD will display in turn with Battery Voltage,
Charging Current, Charged Capacity (Amp-hour) and Battery Temperature (if external
temperature sensor connected).
Display in the daytime-
V
A
Display during the night-
ºC
V
Alternatively Display voltage and FUL when battery is fully charged-
V
8
ºC
V

Charging Stages

You also can visually monitor your battery charging condition via an LCD bar on the top
of LCD meter, if the battery is in the charging process, the LCD bar will be flashing; if the
battery is fully charged, the LCD bar will turn on.
The VOLT / AMP button can be changed at any time during charging process.
The LCD also can be treated as an independent voltage meter or thermometer. A voltage
less than 11.5V Volts indicates that the battery is discharged and needs re-charging.
CHARGING STAGES
The unit has a 5-stage charging algorithm.
Soft Charge (Level 1) –Bulk Charge (Level 2)-Absorption charge (Level 3) – Equalizing Charge*
(Level 4) - Float Mode (Level 5)
Level 3
Level 2
Level 1
Soft Charge- When batteries suffer an over-discharge, the controller will softly ramp the
battery voltage up to 10V.
Bulk Charge- Maximum current charging until batteries rise to Absorption level
Level 4
Level 5