U S E R M A N U A L
TECHNICAL DATA
Parameter
Parameter value
description
Product name
KNIFE STERILISER
Model
RC-KSSS201
RC-KSSS501
Rated voltage
[V~] / Frequency
220-240/ 50-60
[Hz]
Rated power [W]
8,0
Number of
14,0
20,0
knives
Magnetic strip
308,0
398,0
length [mm]
Maximum
working time
0-60
[min]
Dimensions
570x350x125
590x440x125
[mm]
Weight [kg]
5,0
5,9
1. GENERAL DESCRIPTION
The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines,
using
state-of-the-art
technologies
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
USER MANUAL.
To increase the product life of the device and to ensure
trouble-free operation, use it in accordance with this user
manual and regularly perform maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement. The device
is designed to reduce noise emission risks to a minimum,
taking into account technological progress and noise
reduction opportunities.
LEGEND
The product satisfies the relevant safety
standards.
Read instructions before use.
The product must be recycled.
WARNING! or CAUTION! or REMEMBER!
Applicable to the given situation. (general
warning sign)
Wear protective goggles.
ATTENTION! Electric shock warning!
6
EN
ATTENTION! Hot surface, risk of burns!
Only use indoors.
WARNING! UV radiation is harmful to health.
Do not expose eyes and skin to the device
UV-C
operation (UVC radiation).
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual product.
The original operation manual is written in German. Other
language versions are translations from the German.
2. USAGE SAFETY
ATTENTION! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury or even death.
The terms „device" or „product" are used in the warnings
and instructions to refer to <KNIFE STERILISER>.
2.1. ELECTRICAL SAFETY
a)
The plug must fit the socket. Do not modify the plug
in any way. Using original plugs and matching sockets
reduces the risk of electric shock.
b)
Do not touch the device with wet or damp hands.
c)
Use the cable only for its designated use. Never use it
to carry the device or to pull the plug out of a socket.
Keep the cable away from heat sources, oil, sharp
and
edges or moving parts. Damaged or tangled cables
increase the risk of electric shock.
d)
If using the device in a damp environment cannot be
avoided, a residual current device (RCD) should be
applied. The use of an RCD reduces the risk of electric
shock.
e)
Do not use the device if the power cord is damaged
or shows obvious signs of wear. A damaged power
cord should be replaced by a qualified electrician or
the manufacturer's service centre.
f)
To avoid electric shock, do not immerse the cord, plug
or device in water or other liquids. Do not use the
device on wet surfaces.
g)
ATTENTION! DANGER TO LIFE! While cleaning, never
immerse the device in water or other liquids.
2.2. SAFETY IN THE WORKPLACE
a)
Make sure the workplace is clean and well lit. A messy
or poorly lit workplace may lead to accidents. Try
to think ahead, observe what is going on and use
common sense when working with the device.
b)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
c)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
d)
In case of fire, use a powder or carbon dioxide
(CO2) fire extinguisher (one intended for use on live
electrical devices) to put it out.
e)
Please keep this manual available for future reference.
If this device is passed on to a third party, the manual
must be passed on with it.
f)
Keep packaging elements and small assembly parts in
a place not available to children.
g)
Keep the device away from children and animals.
Rev. 11.08.2021
2.3. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
The device is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience and/
or knowledge unless they are supervised by a person
responsible for their safety or they have received
instruction on how to operate the device.
c)
The device can be handled only by physically fit
persons who are capable of handling it, properly
trained, familiar with this manual and trained within
the scope of occupational health and safety.
d)
When working with the device, use common sense
and stay alert. Temporary loss of concentration while
using the device may lead to serious injuries.
e)
Use personal protective equipment as required
for working with the device, specified in section 1
(Legend). The use of correct and approved personal
protective equipment reduces the risk of injury.
f)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
g)
The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
2.4. SAFE DEVICE USE
a)
Do not overload the device. Use the appropriate tools
for the given task. A correctly-selected device will
perform the task for which it was designed better and
in a safer manner.
b)
Make sure the plug is disconnected from the socket
before
attempting
any adjustments,
accessory
replacements or before putting the device aside.
Such precautions will reduce the risk of accidentally
activating the device.
c)
Disconnect the device from the power supply
before commencement of adjustment, cleaning and
maintenance. Such a preventive measure reduces the
risk of accidental activation.
d)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
e)
Keep the device in perfect technical condition. Before
each use check for general damage and especially
check for cracked parts or elements and for any other
conditions which may impact the safe operation of
the device. If damage is discovered, hand over the
device for repair before use.
f)
Device repair or maintenance should be carried out by
qualified persons, only using original spare parts. This
will ensure safe use.
g)
To ensure the operational integrity of the device, do
not remove factory-fitted guards and do not loosen
any screws.
h)
Do not move, adjust or rotate the device in the course
of work.
i)
Clean the device regularly to prevent stubborn grime
from accumulating.
j)
The device is not a toy. Cleaning and maintenance may
not be carried out by children without supervision by
an adult person.
Rev. 11.08.2021
EN
k)
It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there is
still a slight risk of accident or injury when using the
device. Stay alert and use common sense when using
the device.
3. USE GUIDELINES
The device should be fixed to the wall using the holes on
the back of the casing.
The product is outside the scope of MDD93/42/EEC
regulations for medical devices.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
ATTENTION! This product's exploded view can be found on
the last pages of the operating instructions (pp. 24).
1.
Protective plate
2.
reinforcement
3.
Casing
4.
Timer
5.
Switch
6.
LEDs
7.
Ultraviolet light lamp
8.
Hinge
9.
Door
10.
Handle
11.
Magnetic lock
12.
Vice
13.
Power cable
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. Keep the product away from hot surfaces.
The device should always be used when positioned on an
even, stable, clean, fireproof and dry surface, and be out
of the reach of children and persons with limited mental
and sensory functions. Position the device such that you
always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
ASSEMBLING THE DEVICE
The device should be fixed to the wall using the holes on
the back of the casing.
3.3. DEVICE USE
PLEASE NOTE: The safety switch turns off the lamps when
the appliance door is opened. The device must be used in
an upright position regardless where it has been installed.
USE
When you have cleaned the knives, place them inside the
device on a magnetic lamp and select a time from 0 to 1
hour on the knob. Both green and red LEDs will light. The
green light informs about the working time of the device,
while the red light about power supply the device. After
7