Description
CCD 1/3" monochromatic camera.
Supply the camera with 230V a.c. 50 Hz.
Adjust the lens focus and the diaphragm (when manual
diaphragm lenses are used) to optimise the picture.
Lenses
Use lenses with CS coupling. Lenses with C pitch can also be
used with adapter (supplied). If lenses with automatic diaphragm
IRIS terminal
Camera
Name of the parts and functions
1 - Lens coupling: CS lens
2 - Camera fastening screw: on the wall, in a case etc.
3 - IRIS terminal: connect when an automatic diaphragm is
used.
4 - Connector for video output (BNC)
5 - Power supply cord: connect to the 230V a.c. 50Hz mains
6 - Shutter switch: to start the mode (automatic electronic
shutter) with manual diaphragm lenses, position on ON.
Position on SH when using automatic diaphragm lenses
7 - AUTO IRIS switch: position on VIDEO for lenses with ampli-
fier, position on DC for lenses without amplifier.
8 - LED, power supply ON indicator
9 - DC VR potentiometer to adjust the video output level when
using lenses with automatic IRIS.
Features
Power supply
230Va.c. +/- 10% / 50 +/- 1 Hz
Absorption
100 mA
Detector
1/3" black and white CCD
with interline transfer.
Picture elements
Total :
Effective :
Scanning system
EIA standard 525 lines, 30 frames/sec.
CCIR standard 625 lines, 25 frames/sec.
Tuning system
Internal
Resolution
420 TV lines
Minimum lighting
0.15 Lux / F1.2
Range
0.45
Signal/noise ratio
46 db (AGC OFF)
Electronic shutter
EIA
CCIR (1/50 – 1/100000)
Automatic diaphragm
4p connector (DC – VIDEO)
Output signal
1,0 Vpp composite – 75 ohm
Operating temperature
- 10°C
Dimensions (mm)
50 (l) x 50 (h) x 130 (p)
Weight
560g
All manuals and user guides at all-guides.com
Lens
Welding side
EIA 537(H) x 505 (V)
CCIR
537(H) x 597 (V)
EIA 510(H) x 492 (V)
CCIR
500(H) x 582 (V)
(1/60 – 1/100000)
+50°C
are used connect the lens connector to the IRIS terminal on the
back of the camera.
Note
: Using lenses with motorised zoom in the external case
Item 391803, as well as fastening the lens to the internal support
bracket, the camera should also be fastened to it, screwing the
spacer provided to the camera body.
The camera is supplied in standard back focus position. An
adjustment may be necessary, however, for some types of lens
with zoom.
1
2
1
4
3
2
3
4
50 mm
130 mm
Side view
1
Warnings
- Do not turn the camera towards the sun.
- Do not point the camera towards the sun even if it is not fil-
ming.
- Do not film when the light is too bright.
- Do not drop the camera, do not subject it to blows and vibra-
tions.
- Do not touch internal parts.
- Install the camera in a place where it cannot get wet. If it gets
wet, detach it from the power supply immediately and contact
the after-sales service.
- Install the camera away from video noise sources.
When the camera cables are laid near to electrical conductors
or antennae for televisions, there may be interference on the
picture. If this happens, reposition the cables or reinstall the
device.
- Check the ambient temperature and humidity.
The picture quality may be worsened or some parts inside the
camera may be subject to faults, if the ambient temperature is
higher or lower than that indicated in the specifications.
The camera should not be used in these circumstances.
Precautions should also be taken if there is a high degree of
humidity.
GB
IRIS TERMINAL
DC position
VIDEO position
9V IRIS feed
Control
(50mA max)
Control
GND
0.8Vpp
Drive
Video signal
Drive
(GND)
GND
4
2
Lower view
6
7
9
IRIS OUT
DN
DC
SH
VIDEO
4
DC VR
VIDEO OUT
POWER
4
8
7
3
5